Cl对Au-Al和Cu-Al HTS和bast线键可靠性性能影响的比较

Wang Bisheng, Lois Liao Jinzhi, Zhang Xi, Li Xiaomin, H. Younan, Tee Weikok, Yee Boonhwa, Mao Songlin, Yao Qinghong
{"title":"Cl对Au-Al和Cu-Al HTS和bast线键可靠性性能影响的比较","authors":"Wang Bisheng, Lois Liao Jinzhi, Zhang Xi, Li Xiaomin, H. Younan, Tee Weikok, Yee Boonhwa, Mao Songlin, Yao Qinghong","doi":"10.1109/IPFA47161.2019.8984918","DOIUrl":null,"url":null,"abstract":"Wire bond industry is transitioning from Au (gold) bonding wire to Cu (copper) bonding wire, due to the high cost of Au and comparatively much lower cost and good electricity conductivity of Cu. Whilst Cu is less reliable than Au. Cu is susceptible to corrosion especially under the presence of moisture and Cl (chloride). In this work, Au and Cu wires were ball bonded to Al pad and molded with EMC (epoxy mold compound) with different ranges of Cl. Cl was purposely added into EMC to trigger the failure. All EMC samples were prepared with pH range of 5 – 7. Reliability tests bHAST (biased highly accelerated stress test) and HTS (high temperature storage test) were conducted. The results showed that under dry condition, Cl was not easy to attack the wire bond, and failure did not occur unless high content of Cl (up to 500ppm) was present. On the contrary, under humid environment, even several ppm content of Cl would cause failure of Cu-Al wire bond. By comparison, under humid environment, as Au-Al wire bond formed corrosion products which locked the Cl, therefore Cl could not repeatedly serve as a catalyst. Au-Al failure occurred only with high ppm content of Cl (up to 500ppm). In addition, it is found that Cl will promote the Au-Al IMC growth in HTS and bHAST.","PeriodicalId":169775,"journal":{"name":"2019 IEEE 26th International Symposium on Physical and Failure Analysis of Integrated Circuits (IPFA)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Comparison of Cl effect on Au-Al and Cu-Al HTS and bHAST wire bond reliability performance\",\"authors\":\"Wang Bisheng, Lois Liao Jinzhi, Zhang Xi, Li Xiaomin, H. Younan, Tee Weikok, Yee Boonhwa, Mao Songlin, Yao Qinghong\",\"doi\":\"10.1109/IPFA47161.2019.8984918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Wire bond industry is transitioning from Au (gold) bonding wire to Cu (copper) bonding wire, due to the high cost of Au and comparatively much lower cost and good electricity conductivity of Cu. Whilst Cu is less reliable than Au. Cu is susceptible to corrosion especially under the presence of moisture and Cl (chloride). In this work, Au and Cu wires were ball bonded to Al pad and molded with EMC (epoxy mold compound) with different ranges of Cl. Cl was purposely added into EMC to trigger the failure. All EMC samples were prepared with pH range of 5 – 7. Reliability tests bHAST (biased highly accelerated stress test) and HTS (high temperature storage test) were conducted. The results showed that under dry condition, Cl was not easy to attack the wire bond, and failure did not occur unless high content of Cl (up to 500ppm) was present. On the contrary, under humid environment, even several ppm content of Cl would cause failure of Cu-Al wire bond. By comparison, under humid environment, as Au-Al wire bond formed corrosion products which locked the Cl, therefore Cl could not repeatedly serve as a catalyst. Au-Al failure occurred only with high ppm content of Cl (up to 500ppm). In addition, it is found that Cl will promote the Au-Al IMC growth in HTS and bHAST.\",\"PeriodicalId\":169775,\"journal\":{\"name\":\"2019 IEEE 26th International Symposium on Physical and Failure Analysis of Integrated Circuits (IPFA)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 26th International Symposium on Physical and Failure Analysis of Integrated Circuits (IPFA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPFA47161.2019.8984918\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 26th International Symposium on Physical and Failure Analysis of Integrated Circuits (IPFA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPFA47161.2019.8984918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

由于金(Au)焊线成本高,而铜(Cu)焊线成本相对较低且导电性好,因此线粘接行业正在从Au(金)焊线向Cu(铜)焊线过渡。而铜则不如金可靠。铜易受腐蚀,特别是在湿气和氯离子存在的情况下。在这项工作中,Au和Cu导线被球接在Al衬垫上,并用不同Cl范围的EMC(环氧模化合物)成型。Cl被故意添加到EMC中以触发故障。所有EMC样品均在pH值5 ~ 7范围内制备。可靠性测试进行了bast(偏置高加速应力测试)和HTS(高温储存测试)。结果表明,在干燥条件下,Cl不容易侵蚀焊丝,除非Cl含量很高(高达500ppm),否则不会发生焊丝粘结失效。相反,在潮湿环境下,即使是几个ppm的Cl含量也会导致铜铝丝结合失效。相比之下,在潮湿环境下,由于Au-Al线键形成的腐蚀产物锁住了Cl,因此Cl不能重复起到催化剂的作用。只有当Cl含量高(高达500ppm)时,才会发生Au-Al失效。此外,还发现Cl会促进HTS和bast中Au-Al IMC的生长。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Cl effect on Au-Al and Cu-Al HTS and bHAST wire bond reliability performance
Wire bond industry is transitioning from Au (gold) bonding wire to Cu (copper) bonding wire, due to the high cost of Au and comparatively much lower cost and good electricity conductivity of Cu. Whilst Cu is less reliable than Au. Cu is susceptible to corrosion especially under the presence of moisture and Cl (chloride). In this work, Au and Cu wires were ball bonded to Al pad and molded with EMC (epoxy mold compound) with different ranges of Cl. Cl was purposely added into EMC to trigger the failure. All EMC samples were prepared with pH range of 5 – 7. Reliability tests bHAST (biased highly accelerated stress test) and HTS (high temperature storage test) were conducted. The results showed that under dry condition, Cl was not easy to attack the wire bond, and failure did not occur unless high content of Cl (up to 500ppm) was present. On the contrary, under humid environment, even several ppm content of Cl would cause failure of Cu-Al wire bond. By comparison, under humid environment, as Au-Al wire bond formed corrosion products which locked the Cl, therefore Cl could not repeatedly serve as a catalyst. Au-Al failure occurred only with high ppm content of Cl (up to 500ppm). In addition, it is found that Cl will promote the Au-Al IMC growth in HTS and bHAST.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信