{"title":"电容和电阻层析传感器的三维效应","authors":"Jiangtao Sun, Wuqiang Yang","doi":"10.1109/IST.2012.6295557","DOIUrl":null,"url":null,"abstract":"In electrical resistance tomography (ERT) sensors, small pin electrodes are commonly used. It is well known that the pin electrodes cause severe field distortions or 3D effect, and the sensing region of such an ERT sensor is not constrained to the pin electrode plane, but spreads to a large volume. This is also true for electrical capacitance tomography (ECT) sensors, even though it is less severe because of larger size electrodes in ECT sensors. However, when the length of electrodes in an ECT sensor is reduced to almost the same dimension as those in ERT sensor, the 3D effect may be equally obvious. To investigate the 3D effect of ERT and ECT sensors, simulation was carried out with different lengths of electrodes and the results are compared with the corresponding 2D simulation. It is concluded that sensors with longer electrodes usually have less 3D effect without guard electrodes. To investigate the effectiveness of grounded guards, 3D simulation was carried out for ECT sensors with grounded guards and the results are compared with the previous results in term of the 3D effect. It is found that the 3D effects of ECT and ERT sensors without guards are similar to each other, and the grounded guards can reduce the 3D effect of ECT sensors to a great extent.","PeriodicalId":213330,"journal":{"name":"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"3D effect of electrical capacitance and resistance tomography sensors\",\"authors\":\"Jiangtao Sun, Wuqiang Yang\",\"doi\":\"10.1109/IST.2012.6295557\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In electrical resistance tomography (ERT) sensors, small pin electrodes are commonly used. It is well known that the pin electrodes cause severe field distortions or 3D effect, and the sensing region of such an ERT sensor is not constrained to the pin electrode plane, but spreads to a large volume. This is also true for electrical capacitance tomography (ECT) sensors, even though it is less severe because of larger size electrodes in ECT sensors. However, when the length of electrodes in an ECT sensor is reduced to almost the same dimension as those in ERT sensor, the 3D effect may be equally obvious. To investigate the 3D effect of ERT and ECT sensors, simulation was carried out with different lengths of electrodes and the results are compared with the corresponding 2D simulation. It is concluded that sensors with longer electrodes usually have less 3D effect without guard electrodes. To investigate the effectiveness of grounded guards, 3D simulation was carried out for ECT sensors with grounded guards and the results are compared with the previous results in term of the 3D effect. It is found that the 3D effects of ECT and ERT sensors without guards are similar to each other, and the grounded guards can reduce the 3D effect of ECT sensors to a great extent.\",\"PeriodicalId\":213330,\"journal\":{\"name\":\"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IST.2012.6295557\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IST.2012.6295557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

在电阻层析成像(ERT)传感器中,通常使用小针脚电极。众所周知,引脚电极会引起严重的场畸变或三维效应,这种ERT传感器的传感区域不局限于引脚电极平面,而是向大体积扩散。电容层析成像(ECT)传感器也是如此,尽管由于ECT传感器的电极尺寸较大,它不那么严重。然而,当将ECT传感器的电极长度缩小到与ERT传感器几乎相同的尺寸时,3D效果可能同样明显。为了研究ERT和ECT传感器的三维效果,采用不同长度的电极进行了仿真,并与相应的二维仿真结果进行了比较。结果表明,在没有保护电极的情况下,电极较长的传感器三维效果较差。为了研究接地保护装置的有效性,对带接地保护装置的ECT传感器进行了三维仿真,并与前人的三维效果进行了比较。研究发现,ECT与不带保护装置的ERT传感器的三维效果相似,接地保护装置可以在很大程度上降低ECT传感器的三维效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
3D effect of electrical capacitance and resistance tomography sensors
In electrical resistance tomography (ERT) sensors, small pin electrodes are commonly used. It is well known that the pin electrodes cause severe field distortions or 3D effect, and the sensing region of such an ERT sensor is not constrained to the pin electrode plane, but spreads to a large volume. This is also true for electrical capacitance tomography (ECT) sensors, even though it is less severe because of larger size electrodes in ECT sensors. However, when the length of electrodes in an ECT sensor is reduced to almost the same dimension as those in ERT sensor, the 3D effect may be equally obvious. To investigate the 3D effect of ERT and ECT sensors, simulation was carried out with different lengths of electrodes and the results are compared with the corresponding 2D simulation. It is concluded that sensors with longer electrodes usually have less 3D effect without guard electrodes. To investigate the effectiveness of grounded guards, 3D simulation was carried out for ECT sensors with grounded guards and the results are compared with the previous results in term of the 3D effect. It is found that the 3D effects of ECT and ERT sensors without guards are similar to each other, and the grounded guards can reduce the 3D effect of ECT sensors to a great extent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信