{"title":"多次传代低温样品:使用白色型细胞8次传代研究固体氢","authors":"M. Mengel, B. Winnewisser, M. Winnewisser","doi":"10.1364/fts.1997.fwa.3","DOIUrl":null,"url":null,"abstract":"The use of a White-type multipass arrangement external to the optical head of a cryostat for Fourier transform spectroscopy of solid H2 was explored in previous work from our laboratory [1, 2]. The present measurements were made by extending from 4 to 8 passes through the cell within the liquid-He vaporization cryostat (Janis Research Inc., Model 10 DT) [3]. This multireflection system was mounted inside the sample chamber of the Bruker IFS 120 HR interferometer as shown in Fig. 1. Water absorptions were minimized by evacuating the whole spectrometer. All six windows of the cryostat and of the sample cell were equipped with an antireflection coating which was optimized for the spectral range 7500 - 9000 cm-1.","PeriodicalId":221045,"journal":{"name":"Fourier Transform Spectroscopy","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multipassing a Cryogenic Sample: Use of a White-Type Cell with 8 Passes for Studying Solid Hydrogen\",\"authors\":\"M. Mengel, B. Winnewisser, M. Winnewisser\",\"doi\":\"10.1364/fts.1997.fwa.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of a White-type multipass arrangement external to the optical head of a cryostat for Fourier transform spectroscopy of solid H2 was explored in previous work from our laboratory [1, 2]. The present measurements were made by extending from 4 to 8 passes through the cell within the liquid-He vaporization cryostat (Janis Research Inc., Model 10 DT) [3]. This multireflection system was mounted inside the sample chamber of the Bruker IFS 120 HR interferometer as shown in Fig. 1. Water absorptions were minimized by evacuating the whole spectrometer. All six windows of the cryostat and of the sample cell were equipped with an antireflection coating which was optimized for the spectral range 7500 - 9000 cm-1.\",\"PeriodicalId\":221045,\"journal\":{\"name\":\"Fourier Transform Spectroscopy\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fourier Transform Spectroscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1364/fts.1997.fwa.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fourier Transform Spectroscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/fts.1997.fwa.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在我们实验室之前的工作中,我们探索了在低温恒温器光学头外部使用white型多通布置进行固体H2的傅里叶变换光谱分析[1,2]。目前的测量是通过在液体- he汽化低温恒温器(Janis Research Inc., Model 10 DT)[3]中从4到8次穿过细胞进行的。该多反射系统安装在布鲁克IFS 120 HR干涉仪的样品室内,如图1所示。通过疏散整个光谱仪来减少水分的吸收。低温恒温器和样品池的6个窗口均覆盖了7500 ~ 9000 cm-1光谱范围优化的增透涂层。
Multipassing a Cryogenic Sample: Use of a White-Type Cell with 8 Passes for Studying Solid Hydrogen
The use of a White-type multipass arrangement external to the optical head of a cryostat for Fourier transform spectroscopy of solid H2 was explored in previous work from our laboratory [1, 2]. The present measurements were made by extending from 4 to 8 passes through the cell within the liquid-He vaporization cryostat (Janis Research Inc., Model 10 DT) [3]. This multireflection system was mounted inside the sample chamber of the Bruker IFS 120 HR interferometer as shown in Fig. 1. Water absorptions were minimized by evacuating the whole spectrometer. All six windows of the cryostat and of the sample cell were equipped with an antireflection coating which was optimized for the spectral range 7500 - 9000 cm-1.