{"title":"基于采样器和VNA的大信号测量系统在连续波和脉冲下的比较","authors":"M. Casbon, P. Tasker","doi":"10.1109/ARFTG.2015.7162890","DOIUrl":null,"url":null,"abstract":"Here we present a comparison of the Large Signal Measurements provided by both a VNA based and a sampler based LSNA system. In this study, in order to achieve a robust and reliable relative phase calibration a dual frequency phase differential method was used. Significantly this work compares measurements performed under both CW and pulse mode operation. Very similar RF I-V waveforms are achieved in both cases, verifying that both architectures can provide comparable measurements not only in CW but also under pulsed operation. The test device was a GaN on silicon carbide HFET.","PeriodicalId":228314,"journal":{"name":"2015 85th Microwave Measurement Conference (ARFTG)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comparison of sampler and VNA based Large Signal Measurement Systems (LSNA) under CW and pulsed operation\",\"authors\":\"M. Casbon, P. Tasker\",\"doi\":\"10.1109/ARFTG.2015.7162890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Here we present a comparison of the Large Signal Measurements provided by both a VNA based and a sampler based LSNA system. In this study, in order to achieve a robust and reliable relative phase calibration a dual frequency phase differential method was used. Significantly this work compares measurements performed under both CW and pulse mode operation. Very similar RF I-V waveforms are achieved in both cases, verifying that both architectures can provide comparable measurements not only in CW but also under pulsed operation. The test device was a GaN on silicon carbide HFET.\",\"PeriodicalId\":228314,\"journal\":{\"name\":\"2015 85th Microwave Measurement Conference (ARFTG)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 85th Microwave Measurement Conference (ARFTG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTG.2015.7162890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 85th Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2015.7162890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of sampler and VNA based Large Signal Measurement Systems (LSNA) under CW and pulsed operation
Here we present a comparison of the Large Signal Measurements provided by both a VNA based and a sampler based LSNA system. In this study, in order to achieve a robust and reliable relative phase calibration a dual frequency phase differential method was used. Significantly this work compares measurements performed under both CW and pulse mode operation. Very similar RF I-V waveforms are achieved in both cases, verifying that both architectures can provide comparable measurements not only in CW but also under pulsed operation. The test device was a GaN on silicon carbide HFET.