毫米波和亚毫米波测量波导法兰设计的改进

M. Horibe, K. Noda
{"title":"毫米波和亚毫米波测量波导法兰设计的改进","authors":"M. Horibe, K. Noda","doi":"10.1109/ARFTG77.2011.6034557","DOIUrl":null,"url":null,"abstract":"Waveguide flange design makes major impact to measurement reproducibility in the range of millimeter and sub-millimeter-wave frequencies, e.g. above 110 GHz. Original concept of flange design, so-call “Oshima” flange, was established in the early 2000s. Its flange alignment is ensured using ring with tight tolerance, however, it is not compatible to MIL-DTL-3922/67C (UG-387) flange. This paper describes a modification of “Oshima” flange in order to establishing a compatibility with UG-387 flange design, and evaluation result of its capability of connection repeatability in the WR-3 (220 GHz–330 GHz) frequency band. Furthermore, the quarter wave length shim, as a TRL “through” line standard, is specially modified to fit with a new design of “Oshima” flange, then, its capability of connection repeatability is also measured and discussed.","PeriodicalId":257372,"journal":{"name":"77th ARFTG Microwave Measurement Conference","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Modification of waveguide flange design for millimeter and submillimeter-wave measurements\",\"authors\":\"M. Horibe, K. Noda\",\"doi\":\"10.1109/ARFTG77.2011.6034557\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Waveguide flange design makes major impact to measurement reproducibility in the range of millimeter and sub-millimeter-wave frequencies, e.g. above 110 GHz. Original concept of flange design, so-call “Oshima” flange, was established in the early 2000s. Its flange alignment is ensured using ring with tight tolerance, however, it is not compatible to MIL-DTL-3922/67C (UG-387) flange. This paper describes a modification of “Oshima” flange in order to establishing a compatibility with UG-387 flange design, and evaluation result of its capability of connection repeatability in the WR-3 (220 GHz–330 GHz) frequency band. Furthermore, the quarter wave length shim, as a TRL “through” line standard, is specially modified to fit with a new design of “Oshima” flange, then, its capability of connection repeatability is also measured and discussed.\",\"PeriodicalId\":257372,\"journal\":{\"name\":\"77th ARFTG Microwave Measurement Conference\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"77th ARFTG Microwave Measurement Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTG77.2011.6034557\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"77th ARFTG Microwave Measurement Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG77.2011.6034557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

波导法兰设计对毫米波和亚毫米波频率范围内的测量再现性有重大影响,例如110 GHz以上。最初的法兰设计概念,即所谓的“大岛”法兰,是在21世纪初建立的。它的法兰对准是通过紧公差环来保证的,然而,它与MIL-DTL-3922/67C (UG-387)法兰不兼容。本文介绍了为与UG-387法兰设计兼容而对“大岛”法兰进行的改进,并对其在WR-3 (220 GHz - 330 GHz)频段的连接可重复性能力进行了评价。此外,对TRL“直通”线标准的四分之一波长垫片进行了特殊修改,以适应新设计的“大岛”法兰,并对其连接可重复性能力进行了测量和讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modification of waveguide flange design for millimeter and submillimeter-wave measurements
Waveguide flange design makes major impact to measurement reproducibility in the range of millimeter and sub-millimeter-wave frequencies, e.g. above 110 GHz. Original concept of flange design, so-call “Oshima” flange, was established in the early 2000s. Its flange alignment is ensured using ring with tight tolerance, however, it is not compatible to MIL-DTL-3922/67C (UG-387) flange. This paper describes a modification of “Oshima” flange in order to establishing a compatibility with UG-387 flange design, and evaluation result of its capability of connection repeatability in the WR-3 (220 GHz–330 GHz) frequency band. Furthermore, the quarter wave length shim, as a TRL “through” line standard, is specially modified to fit with a new design of “Oshima” flange, then, its capability of connection repeatability is also measured and discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信