125MVA电机发电机谐波电流抑制及无功补偿分析

Wang Yingqiao, Yao Lie-ying, Peng Jianfei
{"title":"125MVA电机发电机谐波电流抑制及无功补偿分析","authors":"Wang Yingqiao, Yao Lie-ying, Peng Jianfei","doi":"10.1109/SOFE.2011.6052339","DOIUrl":null,"url":null,"abstract":"The load of 125MVA motor generator on HL-2A is introduced. The frequency of harmonics on the output current is analyzed and it is verified by Fourier decomposition to measured signal. The harmonic current and reactive current on power line of generator are calculated from its phase voltages and currents. The simulation results are helpful for the study of active power filter for 125MVA generator.","PeriodicalId":393592,"journal":{"name":"2011 IEEE/NPSS 24th Symposium on Fusion Engineering","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of harmonic current suppression and reactive power compensation on 125MVA motor generator\",\"authors\":\"Wang Yingqiao, Yao Lie-ying, Peng Jianfei\",\"doi\":\"10.1109/SOFE.2011.6052339\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The load of 125MVA motor generator on HL-2A is introduced. The frequency of harmonics on the output current is analyzed and it is verified by Fourier decomposition to measured signal. The harmonic current and reactive current on power line of generator are calculated from its phase voltages and currents. The simulation results are helpful for the study of active power filter for 125MVA generator.\",\"PeriodicalId\":393592,\"journal\":{\"name\":\"2011 IEEE/NPSS 24th Symposium on Fusion Engineering\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE/NPSS 24th Symposium on Fusion Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SOFE.2011.6052339\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE/NPSS 24th Symposium on Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SOFE.2011.6052339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了HL-2A上125MVA电机发电机的负载情况。分析了输出电流上谐波的频率,并对实测信号进行了傅里叶分解验证。根据发电机的相电压和相电流,计算出发电机电源线上的谐波电流和无功电流。仿真结果对125MVA发电机有源滤波器的研究具有一定的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of harmonic current suppression and reactive power compensation on 125MVA motor generator
The load of 125MVA motor generator on HL-2A is introduced. The frequency of harmonics on the output current is analyzed and it is verified by Fourier decomposition to measured signal. The harmonic current and reactive current on power line of generator are calculated from its phase voltages and currents. The simulation results are helpful for the study of active power filter for 125MVA generator.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信