{"title":"多用途心电图人机界面的高级语言设计(Visual c++)","authors":"C. Ghule, D. Wakde, Gurjinder S. Virdi","doi":"10.1109/ICBPE.2009.5384074","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to introduce a new multipurpose human machine interface (HMI) designed using higher level language. Unlike any other software, wherein if hardware is changed; there is a need to bring subsequent change in the software; this HMI can be used as a general purpose software for ECG analysis with any kind of hardware. The same analyzing system can be used to perform allied other functions. It is used to filter the signal coming from the hardware so as to eradicate any kind of noise present. It not only displays the 12 lead ECG signals on the LCD screen but simultaneously stores it in the memory of the system. Further the ECG analysis system analyzes the stored signal to calculate heart rate, P wave and T wave interval, QRS complex interval, presence of PVCs and other abnormalities, and display the arrhythmia. Finally this software makes use of the GSM module or internet protocol defined so as to send SMS to medical expert, giving details of the possible arrhythmia and asking for possible remark.","PeriodicalId":384086,"journal":{"name":"2009 International Conference on Biomedical and Pharmaceutical Engineering","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of HMI for multipurpose electrocardiography using higher level language (Visual C++)\",\"authors\":\"C. Ghule, D. Wakde, Gurjinder S. Virdi\",\"doi\":\"10.1109/ICBPE.2009.5384074\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this paper is to introduce a new multipurpose human machine interface (HMI) designed using higher level language. Unlike any other software, wherein if hardware is changed; there is a need to bring subsequent change in the software; this HMI can be used as a general purpose software for ECG analysis with any kind of hardware. The same analyzing system can be used to perform allied other functions. It is used to filter the signal coming from the hardware so as to eradicate any kind of noise present. It not only displays the 12 lead ECG signals on the LCD screen but simultaneously stores it in the memory of the system. Further the ECG analysis system analyzes the stored signal to calculate heart rate, P wave and T wave interval, QRS complex interval, presence of PVCs and other abnormalities, and display the arrhythmia. Finally this software makes use of the GSM module or internet protocol defined so as to send SMS to medical expert, giving details of the possible arrhythmia and asking for possible remark.\",\"PeriodicalId\":384086,\"journal\":{\"name\":\"2009 International Conference on Biomedical and Pharmaceutical Engineering\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Biomedical and Pharmaceutical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBPE.2009.5384074\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Biomedical and Pharmaceutical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBPE.2009.5384074","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文的目的是介绍一种采用高级语言设计的新型多用途人机界面。不像任何其他软件,其中,如果硬件改变;需要对软件进行后续更改;该人机界面可作为通用软件,与任何类型的硬件进行心电图分析。同样的分析系统可以用来执行相关的其他功能。它用于过滤来自硬件的信号,以消除存在的任何类型的噪声。它不仅在液晶屏上显示12导联心电信号,而且将其同时存储在系统的存储器中。心电分析系统对存储的信号进行分析,计算心率、P波、T波间隔、QRS复间隔、室性早搏有无等异常,显示心律失常。最后,该软件利用GSM模块或定义的互联网协议,向医疗专家发送短信,详细说明可能出现的心律失常,并要求可能的评论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of HMI for multipurpose electrocardiography using higher level language (Visual C++)
The aim of this paper is to introduce a new multipurpose human machine interface (HMI) designed using higher level language. Unlike any other software, wherein if hardware is changed; there is a need to bring subsequent change in the software; this HMI can be used as a general purpose software for ECG analysis with any kind of hardware. The same analyzing system can be used to perform allied other functions. It is used to filter the signal coming from the hardware so as to eradicate any kind of noise present. It not only displays the 12 lead ECG signals on the LCD screen but simultaneously stores it in the memory of the system. Further the ECG analysis system analyzes the stored signal to calculate heart rate, P wave and T wave interval, QRS complex interval, presence of PVCs and other abnormalities, and display the arrhythmia. Finally this software makes use of the GSM module or internet protocol defined so as to send SMS to medical expert, giving details of the possible arrhythmia and asking for possible remark.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信