三相UPS系统控制器设计与分析

S. Karthikeyan, R. Kumar
{"title":"三相UPS系统控制器设计与分析","authors":"S. Karthikeyan, R. Kumar","doi":"10.1109/SCEECS.2012.6184814","DOIUrl":null,"url":null,"abstract":"A method of high performance output voltage control of four-wire inverter based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the four-wire inverter is developed and the minimum loss discontinuous PWM method is derived. The design and analysis for the four-wire inverter UPS are proposed. Linear and nonlinear loads for balanced and unbalanced load operating conditions are implemented. The scalar control and PWM methods are proposed and implemented in MATLAB simulation.","PeriodicalId":372799,"journal":{"name":"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and analysis of controller for three-phase UPS system\",\"authors\":\"S. Karthikeyan, R. Kumar\",\"doi\":\"10.1109/SCEECS.2012.6184814\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of high performance output voltage control of four-wire inverter based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the four-wire inverter is developed and the minimum loss discontinuous PWM method is derived. The design and analysis for the four-wire inverter UPS are proposed. Linear and nonlinear loads for balanced and unbalanced load operating conditions are implemented. The scalar control and PWM methods are proposed and implemented in MATLAB simulation.\",\"PeriodicalId\":372799,\"journal\":{\"name\":\"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCEECS.2012.6184814\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCEECS.2012.6184814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种基于四线制逆变器的高性能三相UPS输出电压控制方法。采用基于固定框架谐振滤波器组的输出电压控制回路,辅以基于电容电流反馈的主动阻尼回路。利用零状态划分变量,提出了四线制逆变器标量PWM的广义形式,并推导了最小损耗间断PWM方法。提出了四线制逆变式UPS的设计与分析。实现了平衡和不平衡负载工况下的线性和非线性负载。提出了标量控制和PWM控制方法,并在MATLAB仿真中实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and analysis of controller for three-phase UPS system
A method of high performance output voltage control of four-wire inverter based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the four-wire inverter is developed and the minimum loss discontinuous PWM method is derived. The design and analysis for the four-wire inverter UPS are proposed. Linear and nonlinear loads for balanced and unbalanced load operating conditions are implemented. The scalar control and PWM methods are proposed and implemented in MATLAB simulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信