高灵敏度长周期光栅马赫-曾德尔折光计

T. Allsop, D. Webb, I. Bennion
{"title":"高灵敏度长周期光栅马赫-曾德尔折光计","authors":"T. Allsop, D. Webb, I. Bennion","doi":"10.1109/OFS.2002.1000517","DOIUrl":null,"url":null,"abstract":"A refractive index sensing system has been demonstrated, which is based upon an in-line fibre long period grating Mach-Zehnder interferometer with a heterodyne interrogation technique. This sensing system has comparable accuracy to laboratory-based techniques used in industry such as high performance liquid chromatography and UV spectroscopy. The advantage of this system is that measurements can be made in-situ for applications in continuous process control. Compared to other refractive index sensing schemes using LPGs, this approach has two main advantages. Firstly, the system relies on a simple optical interrogation system and therefore has the real potential for being low cost, and secondly, so far as we are aware it provides the highest refractive index resolution reported for any fibre LPG device.","PeriodicalId":147710,"journal":{"name":"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)","volume":"100 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A high sensitivity long period grating Mach-Zehnder refractometer\",\"authors\":\"T. Allsop, D. Webb, I. Bennion\",\"doi\":\"10.1109/OFS.2002.1000517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A refractive index sensing system has been demonstrated, which is based upon an in-line fibre long period grating Mach-Zehnder interferometer with a heterodyne interrogation technique. This sensing system has comparable accuracy to laboratory-based techniques used in industry such as high performance liquid chromatography and UV spectroscopy. The advantage of this system is that measurements can be made in-situ for applications in continuous process control. Compared to other refractive index sensing schemes using LPGs, this approach has two main advantages. Firstly, the system relies on a simple optical interrogation system and therefore has the real potential for being low cost, and secondly, so far as we are aware it provides the highest refractive index resolution reported for any fibre LPG device.\",\"PeriodicalId\":147710,\"journal\":{\"name\":\"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)\",\"volume\":\"100 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OFS.2002.1000517\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OFS.2002.1000517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

介绍了一种基于外差探测技术的光纤长周期光栅马赫-曾德尔干涉仪的折射率传感系统。该传感系统具有相当的精度,以实验室为基础的技术在工业中使用,如高效液相色谱和紫外光谱。该系统的优点是可以在连续过程控制中进行原位测量。与其他使用液化石油气的折射率传感方案相比,该方法具有两个主要优点。首先,该系统依赖于一个简单的光学询问系统,因此具有低成本的真正潜力;其次,据我们所知,它提供了所有光纤液化石油气设备中最高的折射率分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A high sensitivity long period grating Mach-Zehnder refractometer
A refractive index sensing system has been demonstrated, which is based upon an in-line fibre long period grating Mach-Zehnder interferometer with a heterodyne interrogation technique. This sensing system has comparable accuracy to laboratory-based techniques used in industry such as high performance liquid chromatography and UV spectroscopy. The advantage of this system is that measurements can be made in-situ for applications in continuous process control. Compared to other refractive index sensing schemes using LPGs, this approach has two main advantages. Firstly, the system relies on a simple optical interrogation system and therefore has the real potential for being low cost, and secondly, so far as we are aware it provides the highest refractive index resolution reported for any fibre LPG device.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信