中心静脉相关血流感染:提高标本采集意识的研究

Kavita Raja, G. Bridget
{"title":"中心静脉相关血流感染:提高标本采集意识的研究","authors":"Kavita Raja, G. Bridget","doi":"10.4103/JPSIC.JPSIC_26_17","DOIUrl":null,"url":null,"abstract":"Background: Central line associated Blood stream infection(CLA-BSI) is a hospital acquired infection that is often missed. In a patient on a central line, culture of peripheral blood along with a sample of blood taken through the CL or CL tips is imperative, for a better laboratory diagnosis of CLA-BSI. Aim: (1) To compare the number of CLA- BSI detected in 2010 with the number in 2012 after the awareness campaign was conducted in 2011. (2) To compare specimen collection in different units and formulate strategies for improvement. Methods: Using the laboratory information network, the number of cannula tips and blood cultures sent for culture in 2010 was taken. An intensive campaign to detect CLA-BSI, was initiated in 2011 by the Infection Control Team. The total number of CLA-BSI detected in 2010 was then compared with the number in 2012 after this campaign. Results: A total of 158 cannula tips were sent for culture during the year 2010, while in 2012, 276 cannula tips were sampled. In 2010, while incomplete sampling occurred in 39%, this was reduced to 33% in 2012. Number of correctly diagnosed CLA-BSI increased from 13 to 27 cases in 2012. Conclusion: The campaign has led to detection of more correctly defined CLA-BSI and hence, continuing the training in sending samples is essential to collect the correct data of CLA-BSI. The case studies included show the benefits of correctly identifying such infections.","PeriodicalId":310565,"journal":{"name":"Journal of Patient Safety and Infection Control","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Central line-associated bloodstream infection: A study on creating awareness about specimen collection\",\"authors\":\"Kavita Raja, G. Bridget\",\"doi\":\"10.4103/JPSIC.JPSIC_26_17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Central line associated Blood stream infection(CLA-BSI) is a hospital acquired infection that is often missed. In a patient on a central line, culture of peripheral blood along with a sample of blood taken through the CL or CL tips is imperative, for a better laboratory diagnosis of CLA-BSI. Aim: (1) To compare the number of CLA- BSI detected in 2010 with the number in 2012 after the awareness campaign was conducted in 2011. (2) To compare specimen collection in different units and formulate strategies for improvement. Methods: Using the laboratory information network, the number of cannula tips and blood cultures sent for culture in 2010 was taken. An intensive campaign to detect CLA-BSI, was initiated in 2011 by the Infection Control Team. The total number of CLA-BSI detected in 2010 was then compared with the number in 2012 after this campaign. Results: A total of 158 cannula tips were sent for culture during the year 2010, while in 2012, 276 cannula tips were sampled. In 2010, while incomplete sampling occurred in 39%, this was reduced to 33% in 2012. Number of correctly diagnosed CLA-BSI increased from 13 to 27 cases in 2012. Conclusion: The campaign has led to detection of more correctly defined CLA-BSI and hence, continuing the training in sending samples is essential to collect the correct data of CLA-BSI. The case studies included show the benefits of correctly identifying such infections.\",\"PeriodicalId\":310565,\"journal\":{\"name\":\"Journal of Patient Safety and Infection Control\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Patient Safety and Infection Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/JPSIC.JPSIC_26_17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Patient Safety and Infection Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/JPSIC.JPSIC_26_17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:中央静脉相关血流感染(CLA-BSI)是一种医院获得性感染,常被漏诊。对于中心静脉插管的患者,外周血培养以及通过CL或CL尖端采集的血液样本是必要的,以便更好地进行CLA-BSI的实验室诊断。目的:(1)比较2011年开展宣传活动后,2010年和2012年检测到的CLA- BSI数量。(2)比较不同单位的标本采集情况,制定改进策略。方法:利用实验室信息网络,统计2010年送培养的插管针尖数和血培养数。感染控制小组于2011年发起了一项检测CLA-BSI的密集运动。然后将2010年检测到的CLA-BSI总数与2012年的数量进行比较。结果:2010年共送培养158根,2012年共送培养276根。2010年,39%的采样不完整,2012年这一比例降至33%。正确诊断的CLA-BSI从13例增加到2012年的27例。结论:该运动已经导致检测到更正确定义的CLA-BSI,因此,继续发送样本的培训对于收集正确的CLA-BSI数据至关重要。所包括的案例研究显示了正确识别此类感染的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Central line-associated bloodstream infection: A study on creating awareness about specimen collection
Background: Central line associated Blood stream infection(CLA-BSI) is a hospital acquired infection that is often missed. In a patient on a central line, culture of peripheral blood along with a sample of blood taken through the CL or CL tips is imperative, for a better laboratory diagnosis of CLA-BSI. Aim: (1) To compare the number of CLA- BSI detected in 2010 with the number in 2012 after the awareness campaign was conducted in 2011. (2) To compare specimen collection in different units and formulate strategies for improvement. Methods: Using the laboratory information network, the number of cannula tips and blood cultures sent for culture in 2010 was taken. An intensive campaign to detect CLA-BSI, was initiated in 2011 by the Infection Control Team. The total number of CLA-BSI detected in 2010 was then compared with the number in 2012 after this campaign. Results: A total of 158 cannula tips were sent for culture during the year 2010, while in 2012, 276 cannula tips were sampled. In 2010, while incomplete sampling occurred in 39%, this was reduced to 33% in 2012. Number of correctly diagnosed CLA-BSI increased from 13 to 27 cases in 2012. Conclusion: The campaign has led to detection of more correctly defined CLA-BSI and hence, continuing the training in sending samples is essential to collect the correct data of CLA-BSI. The case studies included show the benefits of correctly identifying such infections.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信