{"title":"电阻抗断层扫描在肺容积测定中的应用。","authors":"L A Smulders, A van Oosterom","doi":"10.1088/0143-0815/13/a/032","DOIUrl":null,"url":null,"abstract":"<p><p>Trans-thoracical electrical impedance measurements on a human subject have been performed using the Sheffield equipment. These measured transfer impedances are compared with computed ones, based on an inhomogeneous, torso-shaped volume conductor, for different values of the overall electrical conductivities sigma l and sigma r of left and right lung. Each measured set of impedances is compared with all calculated sets. The remaining (minimum) residual difference epsilon is used as a measure of the goodness of fit, and the values of sigma l and sigma r for which epsilon is minimal are taken as representing the overall conductivities of the lungs. For data measured at various stages within the respiratory cycle, sigma l and sigma r have been determined. The results are found to relate well to physiology: for a measurement taken at maximum expiration sigma l and sigma r indicate almost homogeneity, whereas for end inspiratory level sigma l and sigma r tend towards values of 0.2, which is a realistic value for the relative conductivity of lung tissue.</p>","PeriodicalId":77070,"journal":{"name":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","volume":"13 Suppl A ","pages":"167-70"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/032","citationCount":"0","resultStr":"{\"title\":\"Application of electrical impedance tomography to the determination of lung volume.\",\"authors\":\"L A Smulders, A van Oosterom\",\"doi\":\"10.1088/0143-0815/13/a/032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Trans-thoracical electrical impedance measurements on a human subject have been performed using the Sheffield equipment. These measured transfer impedances are compared with computed ones, based on an inhomogeneous, torso-shaped volume conductor, for different values of the overall electrical conductivities sigma l and sigma r of left and right lung. Each measured set of impedances is compared with all calculated sets. The remaining (minimum) residual difference epsilon is used as a measure of the goodness of fit, and the values of sigma l and sigma r for which epsilon is minimal are taken as representing the overall conductivities of the lungs. For data measured at various stages within the respiratory cycle, sigma l and sigma r have been determined. The results are found to relate well to physiology: for a measurement taken at maximum expiration sigma l and sigma r indicate almost homogeneity, whereas for end inspiratory level sigma l and sigma r tend towards values of 0.2, which is a realistic value for the relative conductivity of lung tissue.</p>\",\"PeriodicalId\":77070,\"journal\":{\"name\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"volume\":\"13 Suppl A \",\"pages\":\"167-70\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/032\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0143-0815/13/a/032\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0143-0815/13/a/032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of electrical impedance tomography to the determination of lung volume.
Trans-thoracical electrical impedance measurements on a human subject have been performed using the Sheffield equipment. These measured transfer impedances are compared with computed ones, based on an inhomogeneous, torso-shaped volume conductor, for different values of the overall electrical conductivities sigma l and sigma r of left and right lung. Each measured set of impedances is compared with all calculated sets. The remaining (minimum) residual difference epsilon is used as a measure of the goodness of fit, and the values of sigma l and sigma r for which epsilon is minimal are taken as representing the overall conductivities of the lungs. For data measured at various stages within the respiratory cycle, sigma l and sigma r have been determined. The results are found to relate well to physiology: for a measurement taken at maximum expiration sigma l and sigma r indicate almost homogeneity, whereas for end inspiratory level sigma l and sigma r tend towards values of 0.2, which is a realistic value for the relative conductivity of lung tissue.