由于参考电导率分布不均匀,应用电位断层成像中的反向投影失真。

N J Avis, D C Barber, B H Brown, M A Kiber
{"title":"由于参考电导率分布不均匀,应用电位断层成像中的反向投影失真。","authors":"N J Avis,&nbsp;D C Barber,&nbsp;B H Brown,&nbsp;M A Kiber","doi":"10.1088/0143-0815/13/a/022","DOIUrl":null,"url":null,"abstract":"<p><p>An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.</p>","PeriodicalId":77070,"journal":{"name":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","volume":"13 Suppl A ","pages":"113-7"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/022","citationCount":"15","resultStr":"{\"title\":\"Back-projection distortions in applied potential tomography images due to non-uniform reference conductivity distributions.\",\"authors\":\"N J Avis,&nbsp;D C Barber,&nbsp;B H Brown,&nbsp;M A Kiber\",\"doi\":\"10.1088/0143-0815/13/a/022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.</p>\",\"PeriodicalId\":77070,\"journal\":{\"name\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"volume\":\"13 Suppl A \",\"pages\":\"113-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/022\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0143-0815/13/a/022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0143-0815/13/a/022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

研究人员进行了一项调查,以确定和量化应用电位断层扫描(APT)图像中的畸变,这些畸变来自于非均匀参考电导率分布的物体。结果表明,图像的畸变取决于参考电导率分布,以及图像是沿着均匀参考电导率分布的假设等势还是沿着真实电导率分布的等势进行反投影形成的。我们认为最后的发现是重要的,因为我们之前持有的期望,类似于Yorkey和Webster(1987)的期望,即沿着参考电导率分布的真实等势的反向投影应该导致准确的重建,被证明是不正确的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Back-projection distortions in applied potential tomography images due to non-uniform reference conductivity distributions.

An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信