{"title":"由于参考电导率分布不均匀,应用电位断层成像中的反向投影失真。","authors":"N J Avis, D C Barber, B H Brown, M A Kiber","doi":"10.1088/0143-0815/13/a/022","DOIUrl":null,"url":null,"abstract":"<p><p>An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.</p>","PeriodicalId":77070,"journal":{"name":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","volume":"13 Suppl A ","pages":"113-7"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/022","citationCount":"15","resultStr":"{\"title\":\"Back-projection distortions in applied potential tomography images due to non-uniform reference conductivity distributions.\",\"authors\":\"N J Avis, D C Barber, B H Brown, M A Kiber\",\"doi\":\"10.1088/0143-0815/13/a/022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.</p>\",\"PeriodicalId\":77070,\"journal\":{\"name\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"volume\":\"13 Suppl A \",\"pages\":\"113-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/022\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0143-0815/13/a/022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0143-0815/13/a/022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Back-projection distortions in applied potential tomography images due to non-uniform reference conductivity distributions.
An investigation was conducted to determine and quantify the distortions in applied potential tomography (APT) images reconstructed from data originating from bodies of non-uniform reference conductivity distributions. The results show that the distortions in the images are dependent on the reference conductivity distribution and on whether the images are formed by back projection along the assumed equipotentials of a uniform reference conductivity distribution or along the equipotentials of the true conductivity distribution. We believe that this last finding is significant since our previously held expectation, similar to that of Yorkey and Webster (1987), that back projection along the true equipotentials of the reference conductivity distribution should result in an accurate reconstruction, is shown to be incorrect.