P Liu, H Griffiths, C M Wiles, K M Nathadwarawala, W Stewart
{"title":"电阻抗断层扫描法测量咽传输时间。","authors":"P Liu, H Griffiths, C M Wiles, K M Nathadwarawala, W Stewart","doi":"10.1088/0143-0815/13/a/038","DOIUrl":null,"url":null,"abstract":"<p><p>The feasibility of using electrical impedance tomography (EIT) for measuring pharyngeal transit time has been investigated. Imaging sequences were obtained on the neck in a group of eight healthy subjects when swallowing solutions of different electrical conductivities. The solutions used were aqueous Dioralyte (1.5 S m-1) and tap water (0.04 S m-1). The effects of movement upon the images were large compared with the changes due to the solutions, but these were cancelled by a subtraction technique. The mean value of the EIT pharyngeal transit time parameter was 370 +/- 120 ms. EIT has the advantage that repeated measurements could be performed without fear of hazard in contrast to the established technique of video fluoroscopy which involves ionising</p>","PeriodicalId":77070,"journal":{"name":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","volume":"13 Suppl A ","pages":"197-200"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/038","citationCount":"16","resultStr":"{\"title\":\"Measurement of pharyngeal transit time by electrical impedance tomography.\",\"authors\":\"P Liu, H Griffiths, C M Wiles, K M Nathadwarawala, W Stewart\",\"doi\":\"10.1088/0143-0815/13/a/038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The feasibility of using electrical impedance tomography (EIT) for measuring pharyngeal transit time has been investigated. Imaging sequences were obtained on the neck in a group of eight healthy subjects when swallowing solutions of different electrical conductivities. The solutions used were aqueous Dioralyte (1.5 S m-1) and tap water (0.04 S m-1). The effects of movement upon the images were large compared with the changes due to the solutions, but these were cancelled by a subtraction technique. The mean value of the EIT pharyngeal transit time parameter was 370 +/- 120 ms. EIT has the advantage that repeated measurements could be performed without fear of hazard in contrast to the established technique of video fluoroscopy which involves ionising</p>\",\"PeriodicalId\":77070,\"journal\":{\"name\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"volume\":\"13 Suppl A \",\"pages\":\"197-200\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1088/0143-0815/13/a/038\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0143-0815/13/a/038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0143-0815/13/a/038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
摘要
研究了电阻抗断层扫描(EIT)测量咽传输时间的可行性。在一组8名健康受试者中,当吞咽不同电导率的溶液时,获得了颈部的成像序列。使用的溶液为水透析液(1.5 S m-1)和自来水(0.04 S m-1)。运动对图像的影响比由解引起的变化更大,但这些影响通过减法技术被抵消了。EIT咽部传输时间参数平均值为370±120 ms。与已建立的涉及电离的视频透视技术相比,EIT的优点是可以进行重复测量而不必担心危险
Measurement of pharyngeal transit time by electrical impedance tomography.
The feasibility of using electrical impedance tomography (EIT) for measuring pharyngeal transit time has been investigated. Imaging sequences were obtained on the neck in a group of eight healthy subjects when swallowing solutions of different electrical conductivities. The solutions used were aqueous Dioralyte (1.5 S m-1) and tap water (0.04 S m-1). The effects of movement upon the images were large compared with the changes due to the solutions, but these were cancelled by a subtraction technique. The mean value of the EIT pharyngeal transit time parameter was 370 +/- 120 ms. EIT has the advantage that repeated measurements could be performed without fear of hazard in contrast to the established technique of video fluoroscopy which involves ionising