C. Kao, Chin-Tu Chen
{"title":"二维紧凑型PET系统的性能评估-在系统设计优化中的应用","authors":"C. Kao, Chin-Tu Chen","doi":"10.1109/NSSMIC.2001.1008558","DOIUrl":null,"url":null,"abstract":"In recent years, owing to the need of high spatial resolution and high detection sensitivity for the use of PET in molecular imaging, there has been a growing interest in the development of compact PET systems. Unfortunately, this particular PET configuration has been prohibited by the presence of parallax errors. In recent studies, we have proposed a new design concept for building cost-effective compact PET systems by embedding sinogram restoration methods for removing parallax errors in the output by exploiting redundant information present in the acquired data. In this work, we consider the task of evaluating and comparing the performance of various compact PET systems. The results of this study will provide important design guidelines for building compact PET systems subject to various performance and cost constraints.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"26 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of 2D compact PET systems - with applications to system design optimization\",\"authors\":\"C. Kao, Chin-Tu Chen\",\"doi\":\"10.1109/NSSMIC.2001.1008558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, owing to the need of high spatial resolution and high detection sensitivity for the use of PET in molecular imaging, there has been a growing interest in the development of compact PET systems. Unfortunately, this particular PET configuration has been prohibited by the presence of parallax errors. In recent studies, we have proposed a new design concept for building cost-effective compact PET systems by embedding sinogram restoration methods for removing parallax errors in the output by exploiting redundant information present in the acquired data. In this work, we consider the task of evaluating and comparing the performance of various compact PET systems. The results of this study will provide important design guidelines for building compact PET systems subject to various performance and cost constraints.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"26 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1008558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

近年来,由于PET在分子成像中的应用需要高空间分辨率和高检测灵敏度,人们对紧凑型PET系统的发展越来越感兴趣。不幸的是,由于视差误差的存在,这种特殊的PET配置被禁止了。在最近的研究中,我们提出了一种新的设计概念,通过嵌入正弦图恢复方法来利用所获取数据中的冗余信息消除输出中的视差误差,从而构建具有成本效益的紧凑PET系统。在这项工作中,我们考虑的任务是评估和比较各种紧凑的PET系统的性能。这项研究的结果将为构建紧凑型PET系统提供重要的设计指导方针,这些系统受到各种性能和成本的限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance evaluation of 2D compact PET systems - with applications to system design optimization
In recent years, owing to the need of high spatial resolution and high detection sensitivity for the use of PET in molecular imaging, there has been a growing interest in the development of compact PET systems. Unfortunately, this particular PET configuration has been prohibited by the presence of parallax errors. In recent studies, we have proposed a new design concept for building cost-effective compact PET systems by embedding sinogram restoration methods for removing parallax errors in the output by exploiting redundant information present in the acquired data. In this work, we consider the task of evaluating and comparing the performance of various compact PET systems. The results of this study will provide important design guidelines for building compact PET systems subject to various performance and cost constraints.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信