大功率集成电路单相被动烃类浸没冷却

W. Luiten
{"title":"大功率集成电路单相被动烃类浸没冷却","authors":"W. Luiten","doi":"10.1109/THERMINIC52472.2021.9626533","DOIUrl":null,"url":null,"abstract":"Immersion cooling of data-center boards in dielectric fluid is replacing forced air cooling in view of increased power dissipations and growing environmental concerns. The choice of the dielectric fluid presents as a conflict between environmental and heat transfer properties. Hydrocarbon fluids have good environmental properties, but high viscosity, which is unfavorable for flow. This paper investigates passive single phase hydrocarbon immersion cooling as a substitute for forced air cooling on boards with high-power ICs. An analytical flat plate model is used for first estimations followed by CFD simulations on a state-of-the-art 500 W high-power IC, board and heatsink assembly in a 2U (90 mm) immersion cassette. A virtual response surface Design Of Experiments is used to optimize the fin configuration of the heatsink for 300 – 700 W IC dissipations in a 1U (45 mm) immersion cassette. In addition, the effect of position and the effect of multiple boards is investigated for the optimal heatsink configuration. Single phase passive hydrocarbon immersion cooling is shown to have better cooling performance on the existing design, and the optimized fin geometry demonstrates close to a factor 3 better volumetric cooling performance compared to 3 m/s forced air cooling.","PeriodicalId":302492,"journal":{"name":"2021 27th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Single Phase Passive Hydrocarbon Immersion Cooling of High-power ICs\",\"authors\":\"W. Luiten\",\"doi\":\"10.1109/THERMINIC52472.2021.9626533\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Immersion cooling of data-center boards in dielectric fluid is replacing forced air cooling in view of increased power dissipations and growing environmental concerns. The choice of the dielectric fluid presents as a conflict between environmental and heat transfer properties. Hydrocarbon fluids have good environmental properties, but high viscosity, which is unfavorable for flow. This paper investigates passive single phase hydrocarbon immersion cooling as a substitute for forced air cooling on boards with high-power ICs. An analytical flat plate model is used for first estimations followed by CFD simulations on a state-of-the-art 500 W high-power IC, board and heatsink assembly in a 2U (90 mm) immersion cassette. A virtual response surface Design Of Experiments is used to optimize the fin configuration of the heatsink for 300 – 700 W IC dissipations in a 1U (45 mm) immersion cassette. In addition, the effect of position and the effect of multiple boards is investigated for the optimal heatsink configuration. Single phase passive hydrocarbon immersion cooling is shown to have better cooling performance on the existing design, and the optimized fin geometry demonstrates close to a factor 3 better volumetric cooling performance compared to 3 m/s forced air cooling.\",\"PeriodicalId\":302492,\"journal\":{\"name\":\"2021 27th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 27th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/THERMINIC52472.2021.9626533\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 27th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THERMINIC52472.2021.9626533","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

考虑到耗电量增加和环境问题日益严重,数据中心板在介质流体中的浸没冷却正在取代强制空气冷却。介电流体的选择表现为环境性能和传热性能之间的冲突。烃类流体具有良好的环境性能,但粘度高,不利于流动。本文研究了被动单相碳氢化合物浸没冷却作为大功率集成电路板强制风冷的替代方法。分析平板模型用于首次估计,然后在最先进的500 W大功率IC,板和散热器组件上进行CFD模拟,该组件位于2U (90 mm)浸入式盒式中。虚拟响应面实验设计用于优化散热器的翅片配置,以满足1U (45 mm)浸入式机箱中300 - 700 W IC的耗散。此外,还研究了位置的影响和多板的影响,以获得最佳的散热器配置。在现有设计上,单相被动碳氢化合物浸没冷却具有更好的冷却性能,优化后的翅片几何形状与3m /s强制空气冷却相比,其体积冷却性能提高了近3倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Single Phase Passive Hydrocarbon Immersion Cooling of High-power ICs
Immersion cooling of data-center boards in dielectric fluid is replacing forced air cooling in view of increased power dissipations and growing environmental concerns. The choice of the dielectric fluid presents as a conflict between environmental and heat transfer properties. Hydrocarbon fluids have good environmental properties, but high viscosity, which is unfavorable for flow. This paper investigates passive single phase hydrocarbon immersion cooling as a substitute for forced air cooling on boards with high-power ICs. An analytical flat plate model is used for first estimations followed by CFD simulations on a state-of-the-art 500 W high-power IC, board and heatsink assembly in a 2U (90 mm) immersion cassette. A virtual response surface Design Of Experiments is used to optimize the fin configuration of the heatsink for 300 – 700 W IC dissipations in a 1U (45 mm) immersion cassette. In addition, the effect of position and the effect of multiple boards is investigated for the optimal heatsink configuration. Single phase passive hydrocarbon immersion cooling is shown to have better cooling performance on the existing design, and the optimized fin geometry demonstrates close to a factor 3 better volumetric cooling performance compared to 3 m/s forced air cooling.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信