局部放电-一个有价值的定子绕组评估工具

P. Maughan
{"title":"局部放电-一个有价值的定子绕组评估工具","authors":"P. Maughan","doi":"10.1109/ELINSL.2006.1665339","DOIUrl":null,"url":null,"abstract":"This paper has been prepared to illustrate the value of partial discharge (PD) testing in assessing the condition of stator windings on operating generators and motors. Because of the magnitude of the data base accumulated by one particular PD system vendor during the last 15-20 years, this data base was chosen for study. It was felt that sufficient data had been accumulated to allow useful statistical analysis of the capabilities of PD testing. This paper is based somewhat narrowly on data from only one company; however, there are several other companies involved in PD testing and evaluation. As described below in this paper, these companies have also been successful in identifying stator winding problems through the use of PD equipment. PD monitoring systems appear to be finding conditions of concern on about 6% of generators where the equipment is installed. Probably no other generator monitoring system exceeds this rate of problem detection. Because of the power of PD testing, it is hoped and expected that use of PD monitoring will continue to expand at a significant rate in both utility and industrial power plants","PeriodicalId":427638,"journal":{"name":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","volume":"1140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Partial discharge-a valuable stator winding evaluation tool\",\"authors\":\"P. Maughan\",\"doi\":\"10.1109/ELINSL.2006.1665339\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper has been prepared to illustrate the value of partial discharge (PD) testing in assessing the condition of stator windings on operating generators and motors. Because of the magnitude of the data base accumulated by one particular PD system vendor during the last 15-20 years, this data base was chosen for study. It was felt that sufficient data had been accumulated to allow useful statistical analysis of the capabilities of PD testing. This paper is based somewhat narrowly on data from only one company; however, there are several other companies involved in PD testing and evaluation. As described below in this paper, these companies have also been successful in identifying stator winding problems through the use of PD equipment. PD monitoring systems appear to be finding conditions of concern on about 6% of generators where the equipment is installed. Probably no other generator monitoring system exceeds this rate of problem detection. Because of the power of PD testing, it is hoped and expected that use of PD monitoring will continue to expand at a significant rate in both utility and industrial power plants\",\"PeriodicalId\":427638,\"journal\":{\"name\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"volume\":\"1140 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2006.1665339\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2006.1665339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

本文旨在说明局部放电(PD)试验在评估发电机和电动机运行中的定子绕组状况方面的价值。由于一个特定的PD系统供应商在过去15-20年间积累的数据库的规模,选择该数据库进行研究。人们认为,已经积累了足够的数据,可以对PD测试的能力进行有用的统计分析。这篇论文只基于一家公司的数据;然而,还有其他几家公司参与PD测试和评估。如本文下文所述,这些公司还通过使用PD设备成功地识别了定子绕组问题。PD监测系统似乎在安装了该设备的约6%的发电机上发现了问题。可能没有其他的发电机监控系统超过这个问题检测率。由于局部放电测试的强大功能,人们希望并期望在公用事业和工业发电厂中使用局部放电监测将继续以显着的速度扩展
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Partial discharge-a valuable stator winding evaluation tool
This paper has been prepared to illustrate the value of partial discharge (PD) testing in assessing the condition of stator windings on operating generators and motors. Because of the magnitude of the data base accumulated by one particular PD system vendor during the last 15-20 years, this data base was chosen for study. It was felt that sufficient data had been accumulated to allow useful statistical analysis of the capabilities of PD testing. This paper is based somewhat narrowly on data from only one company; however, there are several other companies involved in PD testing and evaluation. As described below in this paper, these companies have also been successful in identifying stator winding problems through the use of PD equipment. PD monitoring systems appear to be finding conditions of concern on about 6% of generators where the equipment is installed. Probably no other generator monitoring system exceeds this rate of problem detection. Because of the power of PD testing, it is hoped and expected that use of PD monitoring will continue to expand at a significant rate in both utility and industrial power plants
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信