光致变色隐形眼镜对视觉质量和瞳孔直径影响的评价:横断面研究

E. Muhafiz, Ş. Nizamoğulları
{"title":"光致变色隐形眼镜对视觉质量和瞳孔直径影响的评价:横断面研究","authors":"E. Muhafiz, Ş. Nizamoğulları","doi":"10.5336/ophthal.2021-87854","DOIUrl":null,"url":null,"abstract":"ABS TRACT Objective: To evaluate the effects of photochromic con- tact lenses (CL) on contrast sensitivity, aberrations and pupillary diameter in indoor environments. Material and Methods: Contrast sensitivity of the participants was measured and their pupillography under scotopic, mesopic and photopic illumination and topography were taken. Transparent senofilcon A (Acuvue Oasys hydraLuxe) CL was inserted to one eye of the subjects and photochromic senofilcon A (Acuvue Oasys with transitions) CL was inserted to the other eye. Sub-sequently, contrast sensitivity of subjects was measured, pupillography and topography were taken again over the CL. Aberration values were obtained from the topography. In terms of occurred changes, the eye with photochromic CL was compared with the other eye. Results: Before CL insertion, there was no significant difference between the pho- tochromic side and the other side in terms of all parameters examined (for all; p>0.05). After CL insertion, there was no significant change in scotopic, mesopic and photopic pupil diameters on both the photochromic and transparent sides compared to the pre-CL condition (for all; p>0.05), high order aberrations increased (p<0.05), and contrast sensitivity at high frequencies (12 and 18 cpd) decreased (for both; p<0.05). When the photochromic side was compared with the transparent side after CL insertion, no significant difference was observed in terms of all parameters (for all; p>0.05). Conclusion: Using the photochromic CL in indoors does not lead to different results than the trans- parent CL in terms of visual quality and pupil diameters. Both lenses cause a decrease in contrast sensitivity at high frequencies.","PeriodicalId":190073,"journal":{"name":"Turkiye Klinikleri Journal of Ophthalmology","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Effects of Photochromic Contact Lens on Visual Quality and Pupillary Diameter: Cross-Sectional Study\",\"authors\":\"E. Muhafiz, Ş. Nizamoğulları\",\"doi\":\"10.5336/ophthal.2021-87854\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABS TRACT Objective: To evaluate the effects of photochromic con- tact lenses (CL) on contrast sensitivity, aberrations and pupillary diameter in indoor environments. Material and Methods: Contrast sensitivity of the participants was measured and their pupillography under scotopic, mesopic and photopic illumination and topography were taken. Transparent senofilcon A (Acuvue Oasys hydraLuxe) CL was inserted to one eye of the subjects and photochromic senofilcon A (Acuvue Oasys with transitions) CL was inserted to the other eye. Sub-sequently, contrast sensitivity of subjects was measured, pupillography and topography were taken again over the CL. Aberration values were obtained from the topography. In terms of occurred changes, the eye with photochromic CL was compared with the other eye. Results: Before CL insertion, there was no significant difference between the pho- tochromic side and the other side in terms of all parameters examined (for all; p>0.05). After CL insertion, there was no significant change in scotopic, mesopic and photopic pupil diameters on both the photochromic and transparent sides compared to the pre-CL condition (for all; p>0.05), high order aberrations increased (p<0.05), and contrast sensitivity at high frequencies (12 and 18 cpd) decreased (for both; p<0.05). When the photochromic side was compared with the transparent side after CL insertion, no significant difference was observed in terms of all parameters (for all; p>0.05). Conclusion: Using the photochromic CL in indoors does not lead to different results than the trans- parent CL in terms of visual quality and pupil diameters. Both lenses cause a decrease in contrast sensitivity at high frequencies.\",\"PeriodicalId\":190073,\"journal\":{\"name\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5336/ophthal.2021-87854\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkiye Klinikleri Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5336/ophthal.2021-87854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价光致变色隐形眼镜(CL)在室内环境下对对比敏感度、像差和瞳孔直径的影响。材料与方法:测量被试的对比敏感度,并拍摄他们在暗、中、光照明和地形下的瞳孔分布。将透明senofilcon A (Acuvue Oasys hydraLuxe) CL置入受试者一只眼,将光致变色senofilcon A (Acuvue Oasys with transitions) CL置入另一只眼。随后,测量受试者的对比敏感度,并再次在CL上进行瞳孔成像和地形成像。从地形获得像差值。在发生的变化方面,将光致变色CL眼与另一只眼进行比较。结果:CL插入前,双色侧与双色侧在检查的所有参数上均无显著差异(所有;p > 0.05)。植入CL后,与CL前相比,光致变色侧和透明侧的暗瞳、介瞳和光瞳直径均无显著变化(所有;P >0.05),高阶像差增加(p0.05)。结论:使用在室内中的光致变色CL不会导致不同的结果比反式-父CL的视觉质量和瞳孔直径。两种镜片在高频率下都会导致对比灵敏度的降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the Effects of Photochromic Contact Lens on Visual Quality and Pupillary Diameter: Cross-Sectional Study
ABS TRACT Objective: To evaluate the effects of photochromic con- tact lenses (CL) on contrast sensitivity, aberrations and pupillary diameter in indoor environments. Material and Methods: Contrast sensitivity of the participants was measured and their pupillography under scotopic, mesopic and photopic illumination and topography were taken. Transparent senofilcon A (Acuvue Oasys hydraLuxe) CL was inserted to one eye of the subjects and photochromic senofilcon A (Acuvue Oasys with transitions) CL was inserted to the other eye. Sub-sequently, contrast sensitivity of subjects was measured, pupillography and topography were taken again over the CL. Aberration values were obtained from the topography. In terms of occurred changes, the eye with photochromic CL was compared with the other eye. Results: Before CL insertion, there was no significant difference between the pho- tochromic side and the other side in terms of all parameters examined (for all; p>0.05). After CL insertion, there was no significant change in scotopic, mesopic and photopic pupil diameters on both the photochromic and transparent sides compared to the pre-CL condition (for all; p>0.05), high order aberrations increased (p<0.05), and contrast sensitivity at high frequencies (12 and 18 cpd) decreased (for both; p<0.05). When the photochromic side was compared with the transparent side after CL insertion, no significant difference was observed in terms of all parameters (for all; p>0.05). Conclusion: Using the photochromic CL in indoors does not lead to different results than the trans- parent CL in terms of visual quality and pupil diameters. Both lenses cause a decrease in contrast sensitivity at high frequencies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信