演示了一种基于sagnac干涉仪的16传感器时分复用声传感器阵列,该阵列具有放大遥测和基于偏振的偏置方案

B. Vakoc, M. Digonnet, G. Kino
{"title":"演示了一种基于sagnac干涉仪的16传感器时分复用声传感器阵列,该阵列具有放大遥测和基于偏振的偏置方案","authors":"B. Vakoc, M. Digonnet, G. Kino","doi":"10.1109/OFS.2002.1000569","DOIUrl":null,"url":null,"abstract":"We have previously proposed the use of a Sagnac-interferometer in underwater acoustic sensor array applications. In these proposals, we described a configuration that passively desensitises the delay coil required by the Sagnac interferometer and passively eliminates polarization-induced signal fading (PISF). Additionally, an all-passive polarization-based biasing scheme that yields arbitrarily biased outputs was given. Here, we describe an experimental demonstration of a time-division-multiplexed (TDM) Sagnac-based array including all features described previously and supporting 16 individual sensors with an erbium-doped fiber amplifier (EDFA) telemetry.","PeriodicalId":147710,"journal":{"name":"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Demonstration of a 16-sensor time-division-multiplexed Sagnac-interferometer-based acoustic sensor array with an amplified telemetry and a polarization-based biasing scheme\",\"authors\":\"B. Vakoc, M. Digonnet, G. Kino\",\"doi\":\"10.1109/OFS.2002.1000569\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have previously proposed the use of a Sagnac-interferometer in underwater acoustic sensor array applications. In these proposals, we described a configuration that passively desensitises the delay coil required by the Sagnac interferometer and passively eliminates polarization-induced signal fading (PISF). Additionally, an all-passive polarization-based biasing scheme that yields arbitrarily biased outputs was given. Here, we describe an experimental demonstration of a time-division-multiplexed (TDM) Sagnac-based array including all features described previously and supporting 16 individual sensors with an erbium-doped fiber amplifier (EDFA) telemetry.\",\"PeriodicalId\":147710,\"journal\":{\"name\":\"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OFS.2002.1000569\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 15th Optical Fiber Sensors Conference Technical Digest. OFS 2002(Cat. No.02EX533)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OFS.2002.1000569","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

我们以前曾提出在水声传感器阵列应用中使用sagnac干涉仪。在这些建议中,我们描述了一种被动脱敏Sagnac干涉仪所需的延迟线圈的配置,并被动消除极化引起的信号衰落(PISF)。此外,给出了一种基于偏振的全被动偏置方案,可产生任意偏置输出。在这里,我们描述了一个基于sagnac的时分多路复用(TDM)阵列的实验演示,该阵列包括前面描述的所有特征,并支持16个带有掺铒光纤放大器(EDFA)遥测的单独传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Demonstration of a 16-sensor time-division-multiplexed Sagnac-interferometer-based acoustic sensor array with an amplified telemetry and a polarization-based biasing scheme
We have previously proposed the use of a Sagnac-interferometer in underwater acoustic sensor array applications. In these proposals, we described a configuration that passively desensitises the delay coil required by the Sagnac interferometer and passively eliminates polarization-induced signal fading (PISF). Additionally, an all-passive polarization-based biasing scheme that yields arbitrarily biased outputs was given. Here, we describe an experimental demonstration of a time-division-multiplexed (TDM) Sagnac-based array including all features described previously and supporting 16 individual sensors with an erbium-doped fiber amplifier (EDFA) telemetry.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信