单相并网逆变器系统中LCL滤波单极与双极开关方案的比较研究

D. Marandi, T. Sowmya, B. Babu
{"title":"单相并网逆变器系统中LCL滤波单极与双极开关方案的比较研究","authors":"D. Marandi, T. Sowmya, B. Babu","doi":"10.1109/SCEECS.2012.6184741","DOIUrl":null,"url":null,"abstract":"This paper presents the comparative study between unipolar and bipolar switching scheme for single-phase grid-connected inverter system with filter design on the grid side. For that, LCL filter is considered and its performance for current ripple reduction on grid-side is compared with normal L and LC filter. It is seen that the response for LCL filter show the best results with lower current ripple as compared to L and LC Filter. Further, the obtained results show that the obtained LCL-filter can provide sufficient attenuation of current harmonics and mean while injects a sinusoidal current into the grid for maintaining power quality standard. In addition to that, the method to design the inductor is also included in the paper. The studied system is modeled and simulated in MATLAB Computer simulation environment.","PeriodicalId":372799,"journal":{"name":"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Comparative study between unipolar and bipolar switching scheme with LCL filter for single-phase grid connected inverter system\",\"authors\":\"D. Marandi, T. Sowmya, B. Babu\",\"doi\":\"10.1109/SCEECS.2012.6184741\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the comparative study between unipolar and bipolar switching scheme for single-phase grid-connected inverter system with filter design on the grid side. For that, LCL filter is considered and its performance for current ripple reduction on grid-side is compared with normal L and LC filter. It is seen that the response for LCL filter show the best results with lower current ripple as compared to L and LC Filter. Further, the obtained results show that the obtained LCL-filter can provide sufficient attenuation of current harmonics and mean while injects a sinusoidal current into the grid for maintaining power quality standard. In addition to that, the method to design the inductor is also included in the paper. The studied system is modeled and simulated in MATLAB Computer simulation environment.\",\"PeriodicalId\":372799,\"journal\":{\"name\":\"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCEECS.2012.6184741\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Students' Conference on Electrical, Electronics and Computer Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCEECS.2012.6184741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

本文对单相并网逆变器系统的单极和双极开关方案进行了比较研究,并网侧设计了滤波器。为此,考虑了LCL滤波器,并将其与普通L滤波器和LC滤波器在电网侧抑制电流纹波的性能进行了比较。结果表明,与L滤波器和LC滤波器相比,LCL滤波器的响应效果最好,电流纹波较低。结果表明,该滤波器在向电网注入正弦电流的同时,能够充分地衰减电流的谐波和平均值,从而保持电网的电能质量标准。此外,本文还介绍了电感器的设计方法。在MATLAB计算机仿真环境中对所研究的系统进行了建模和仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative study between unipolar and bipolar switching scheme with LCL filter for single-phase grid connected inverter system
This paper presents the comparative study between unipolar and bipolar switching scheme for single-phase grid-connected inverter system with filter design on the grid side. For that, LCL filter is considered and its performance for current ripple reduction on grid-side is compared with normal L and LC filter. It is seen that the response for LCL filter show the best results with lower current ripple as compared to L and LC Filter. Further, the obtained results show that the obtained LCL-filter can provide sufficient attenuation of current harmonics and mean while injects a sinusoidal current into the grid for maintaining power quality standard. In addition to that, the method to design the inductor is also included in the paper. The studied system is modeled and simulated in MATLAB Computer simulation environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信