M. E. Smith, J. Parsons, N. Langrana, M. Cibischino, C.K. Lee, L. Gustavson, K. Kaiser
{"title":"颈椎稳定装置的生物力学研究","authors":"M. E. Smith, J. Parsons, N. Langrana, M. Cibischino, C.K. Lee, L. Gustavson, K. Kaiser","doi":"10.1109/NEBC.1991.154563","DOIUrl":null,"url":null,"abstract":"The biomechanical properties of surgically destabilized cervical spine motion segments are evaluated. The segments were fixed with spinal fixation plates and tested. The Roy-Camille spinal fixation plates were utilized as the stabilizing device. Results are compared with intact motion segments. It is shown that segments C3-4 and C4-5, when severely destabilized by a surgically created defect, can effectively be restabilized through proper application of Roy-Camille spinal fixation plates. In flexion/extension and torsion the passive range of motion is virtually eliminated in the plated motion segments. Tests to failure of these severely destabilized, plated spines demonstrate failure by screw pull-out.<<ETX>>","PeriodicalId":434209,"journal":{"name":"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A biomechanical study of a cervical spine stabilization device\",\"authors\":\"M. E. Smith, J. Parsons, N. Langrana, M. Cibischino, C.K. Lee, L. Gustavson, K. Kaiser\",\"doi\":\"10.1109/NEBC.1991.154563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The biomechanical properties of surgically destabilized cervical spine motion segments are evaluated. The segments were fixed with spinal fixation plates and tested. The Roy-Camille spinal fixation plates were utilized as the stabilizing device. Results are compared with intact motion segments. It is shown that segments C3-4 and C4-5, when severely destabilized by a surgically created defect, can effectively be restabilized through proper application of Roy-Camille spinal fixation plates. In flexion/extension and torsion the passive range of motion is virtually eliminated in the plated motion segments. Tests to failure of these severely destabilized, plated spines demonstrate failure by screw pull-out.<<ETX>>\",\"PeriodicalId\":434209,\"journal\":{\"name\":\"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1991.154563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1991.154563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A biomechanical study of a cervical spine stabilization device
The biomechanical properties of surgically destabilized cervical spine motion segments are evaluated. The segments were fixed with spinal fixation plates and tested. The Roy-Camille spinal fixation plates were utilized as the stabilizing device. Results are compared with intact motion segments. It is shown that segments C3-4 and C4-5, when severely destabilized by a surgically created defect, can effectively be restabilized through proper application of Roy-Camille spinal fixation plates. In flexion/extension and torsion the passive range of motion is virtually eliminated in the plated motion segments. Tests to failure of these severely destabilized, plated spines demonstrate failure by screw pull-out.<>