{"title":"用声学显微镜测量胶粘剂层","authors":"S. Canumalla","doi":"10.1109/ADHES.1998.742026","DOIUrl":null,"url":null,"abstract":"A procedure for metrology of thin adhesive layers via acoustic microscopy is discussed in this paper. The phenomenon of reflection of ultrasonic pulses at a layered interface is exploited to make these measurements. An experimental jig, where the layer thickness could be varied continuously from near zero to a known value, was used to validate a theoretical model that is used to estimate layer properties. The practical application of measuring the thickness of a layer of heat conducting epoxy sandwiched between the die backside and a heat spreader was analyzed. Results from this theoretical experiment suggest that small changes in material parameters result in measurable changes in the ultrasonic parameters. For example, a change of 1 MHz in the measured frequency parameter corresponds to a 0.4 /spl mu/m variation in the adhesive layer thickness. Since frequency can be measured with accuracy greater than 1 MHz, relatively small variations in layer thickness and material properties could be monitored nondestructively using the C-SAM acoustic microscope.","PeriodicalId":183195,"journal":{"name":"Proceedings of 3rd International Conference on Adhesive Joining and Coating Technology in Electronics Manufacturing 1998 (Cat. No.98EX180)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Metrology of adhesive layers using acoustic microscopy\",\"authors\":\"S. Canumalla\",\"doi\":\"10.1109/ADHES.1998.742026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A procedure for metrology of thin adhesive layers via acoustic microscopy is discussed in this paper. The phenomenon of reflection of ultrasonic pulses at a layered interface is exploited to make these measurements. An experimental jig, where the layer thickness could be varied continuously from near zero to a known value, was used to validate a theoretical model that is used to estimate layer properties. The practical application of measuring the thickness of a layer of heat conducting epoxy sandwiched between the die backside and a heat spreader was analyzed. Results from this theoretical experiment suggest that small changes in material parameters result in measurable changes in the ultrasonic parameters. For example, a change of 1 MHz in the measured frequency parameter corresponds to a 0.4 /spl mu/m variation in the adhesive layer thickness. Since frequency can be measured with accuracy greater than 1 MHz, relatively small variations in layer thickness and material properties could be monitored nondestructively using the C-SAM acoustic microscope.\",\"PeriodicalId\":183195,\"journal\":{\"name\":\"Proceedings of 3rd International Conference on Adhesive Joining and Coating Technology in Electronics Manufacturing 1998 (Cat. No.98EX180)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 3rd International Conference on Adhesive Joining and Coating Technology in Electronics Manufacturing 1998 (Cat. No.98EX180)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ADHES.1998.742026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 3rd International Conference on Adhesive Joining and Coating Technology in Electronics Manufacturing 1998 (Cat. No.98EX180)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ADHES.1998.742026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Metrology of adhesive layers using acoustic microscopy
A procedure for metrology of thin adhesive layers via acoustic microscopy is discussed in this paper. The phenomenon of reflection of ultrasonic pulses at a layered interface is exploited to make these measurements. An experimental jig, where the layer thickness could be varied continuously from near zero to a known value, was used to validate a theoretical model that is used to estimate layer properties. The practical application of measuring the thickness of a layer of heat conducting epoxy sandwiched between the die backside and a heat spreader was analyzed. Results from this theoretical experiment suggest that small changes in material parameters result in measurable changes in the ultrasonic parameters. For example, a change of 1 MHz in the measured frequency parameter corresponds to a 0.4 /spl mu/m variation in the adhesive layer thickness. Since frequency can be measured with accuracy greater than 1 MHz, relatively small variations in layer thickness and material properties could be monitored nondestructively using the C-SAM acoustic microscope.