{"title":"全集成伺服驱动系统机械故障的状态监测","authors":"J. Arellano-Padilla, M. Sumner, C. Gerada","doi":"10.1109/EPEPEMC.2008.4635360","DOIUrl":null,"url":null,"abstract":"A modified motor current signature analysis (MCSA) approach to monitor the performance of a servo drive system using only one set of current transducers at the input side of the rectifier is proposed. The paper introduces a mathematical analysis to determine how the harmonic frequencies related to a fault propagate from the motor to the input inverter, and includes the effect of the DC link components. Experimental results are presented for a permanent magnet servo drive system with faulty bearings to validate the proposed scheme.","PeriodicalId":149421,"journal":{"name":"2008 13th International Power Electronics and Motion Control Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Condition monitoring for mechanical faults in fully integrated servo drive systems\",\"authors\":\"J. Arellano-Padilla, M. Sumner, C. Gerada\",\"doi\":\"10.1109/EPEPEMC.2008.4635360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A modified motor current signature analysis (MCSA) approach to monitor the performance of a servo drive system using only one set of current transducers at the input side of the rectifier is proposed. The paper introduces a mathematical analysis to determine how the harmonic frequencies related to a fault propagate from the motor to the input inverter, and includes the effect of the DC link components. Experimental results are presented for a permanent magnet servo drive system with faulty bearings to validate the proposed scheme.\",\"PeriodicalId\":149421,\"journal\":{\"name\":\"2008 13th International Power Electronics and Motion Control Conference\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 13th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEPEMC.2008.4635360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 13th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPEMC.2008.4635360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Condition monitoring for mechanical faults in fully integrated servo drive systems
A modified motor current signature analysis (MCSA) approach to monitor the performance of a servo drive system using only one set of current transducers at the input side of the rectifier is proposed. The paper introduces a mathematical analysis to determine how the harmonic frequencies related to a fault propagate from the motor to the input inverter, and includes the effect of the DC link components. Experimental results are presented for a permanent magnet servo drive system with faulty bearings to validate the proposed scheme.