基于图像处理的痉挛患者运动学参数测定

Y. Albayrak, Mehmet Dağli, Ozcan Asilkan, A. Yardimci, S. Bilgin, H. Uysal
{"title":"基于图像处理的痉挛患者运动学参数测定","authors":"Y. Albayrak, Mehmet Dağli, Ozcan Asilkan, A. Yardimci, S. Bilgin, H. Uysal","doi":"10.1109/BIYOMUT.2014.7026387","DOIUrl":null,"url":null,"abstract":"In this study, it is aimed to obtain Patella T-Reflex kinesiologic parameters on spasticity patients by using image processing methods and thereby extracting objective data for the evaluation of spasticity patients. For this reason, the movement of Patella T-reflex response to knee joint was recorded with the help of a camera after three LED markers placed on the knee joint. For the correctness of the pattern of the movements, data were compared with two-axis goniometer of Biometric Ltd company and thereby it was shown that the reflex patterns are identical. Thereon, using the software we have developed, the Patella T-reflex kinesiologic parameters were calculated and data were obtained for objective evaluation of the Spasticity patients.","PeriodicalId":428610,"journal":{"name":"2014 18th National Biomedical Engineering Meeting","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Image-processing based determination of kinesiologic parameters of spasticity patients\",\"authors\":\"Y. Albayrak, Mehmet Dağli, Ozcan Asilkan, A. Yardimci, S. Bilgin, H. Uysal\",\"doi\":\"10.1109/BIYOMUT.2014.7026387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, it is aimed to obtain Patella T-Reflex kinesiologic parameters on spasticity patients by using image processing methods and thereby extracting objective data for the evaluation of spasticity patients. For this reason, the movement of Patella T-reflex response to knee joint was recorded with the help of a camera after three LED markers placed on the knee joint. For the correctness of the pattern of the movements, data were compared with two-axis goniometer of Biometric Ltd company and thereby it was shown that the reflex patterns are identical. Thereon, using the software we have developed, the Patella T-reflex kinesiologic parameters were calculated and data were obtained for objective evaluation of the Spasticity patients.\",\"PeriodicalId\":428610,\"journal\":{\"name\":\"2014 18th National Biomedical Engineering Meeting\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 18th National Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIYOMUT.2014.7026387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 18th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2014.7026387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在通过图像处理方法获得痉挛患者髌骨t反射的运动学参数,从而提取客观数据用于痉挛患者的评估。因此,在膝关节上放置三个LED标记后,借助相机记录髌骨t反射对膝关节的运动。为了运动模式的正确性,将数据与Biometric公司的两轴角计进行了比较,从而表明反射模式是相同的。在此基础上,利用我们开发的软件,计算髌骨t反射的运动学参数,获得客观评价痉挛患者的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Image-processing based determination of kinesiologic parameters of spasticity patients
In this study, it is aimed to obtain Patella T-Reflex kinesiologic parameters on spasticity patients by using image processing methods and thereby extracting objective data for the evaluation of spasticity patients. For this reason, the movement of Patella T-reflex response to knee joint was recorded with the help of a camera after three LED markers placed on the knee joint. For the correctness of the pattern of the movements, data were compared with two-axis goniometer of Biometric Ltd company and thereby it was shown that the reflex patterns are identical. Thereon, using the software we have developed, the Patella T-reflex kinesiologic parameters were calculated and data were obtained for objective evaluation of the Spasticity patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信