高压直流输电线路不同接地高度导体的电晕放电特性

Liang Jinxiang, Jiang Lin, Li Weidong, Pen Lei
{"title":"高压直流输电线路不同接地高度导体的电晕放电特性","authors":"Liang Jinxiang, Jiang Lin, Li Weidong, Pen Lei","doi":"10.1109/CICED.2018.8592569","DOIUrl":null,"url":null,"abstract":"The corona discharge characteristic of the conductor is one of the key factors affecting the electromagnetic environment of the project. In order to obtain corona discharge characteristics of conductors with different heights to ground and correction methods for inception corona voltage of conductors with different heights to ground, corona test were carried out in Ultra-high Voltage Test Base in Wuhan with ultraviolet image apparatus. the corona test of conductors of JL/G1A-1250/100 and JL/G lA-1250/70 at different heights to ground were carried out., one single conductor., 6-bundle conductor with bundle space 500mm and 8-bundle conductor with bundle space 550mm were tested separately. The results show that Under DC positive voltage., the corona inception voltage for conductors increased with the rise of the height to ground., different bundle distances., different bundle conductors and one single conductor corona discharge characteristics have some differences; The corona inception voltage between single conductor and different bundle distances conductors have certain functional relationship. By establishing the functional relationship between them., the corona inception voltage of bundle conductors can be calculated by the corona inception voltage value of a single conductor., the value of correction errors can be controlled at less than 13%.","PeriodicalId":142885,"journal":{"name":"2018 China International Conference on Electricity Distribution (CICED)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Corona Discharge Characteristics for Conductors of HVDC Transmission Lines with Different Heights to Groud\",\"authors\":\"Liang Jinxiang, Jiang Lin, Li Weidong, Pen Lei\",\"doi\":\"10.1109/CICED.2018.8592569\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The corona discharge characteristic of the conductor is one of the key factors affecting the electromagnetic environment of the project. In order to obtain corona discharge characteristics of conductors with different heights to ground and correction methods for inception corona voltage of conductors with different heights to ground, corona test were carried out in Ultra-high Voltage Test Base in Wuhan with ultraviolet image apparatus. the corona test of conductors of JL/G1A-1250/100 and JL/G lA-1250/70 at different heights to ground were carried out., one single conductor., 6-bundle conductor with bundle space 500mm and 8-bundle conductor with bundle space 550mm were tested separately. The results show that Under DC positive voltage., the corona inception voltage for conductors increased with the rise of the height to ground., different bundle distances., different bundle conductors and one single conductor corona discharge characteristics have some differences; The corona inception voltage between single conductor and different bundle distances conductors have certain functional relationship. By establishing the functional relationship between them., the corona inception voltage of bundle conductors can be calculated by the corona inception voltage value of a single conductor., the value of correction errors can be controlled at less than 13%.\",\"PeriodicalId\":142885,\"journal\":{\"name\":\"2018 China International Conference on Electricity Distribution (CICED)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 China International Conference on Electricity Distribution (CICED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CICED.2018.8592569\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICED.2018.8592569","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

导线的电晕放电特性是影响工程电磁环境的关键因素之一。为了获得不同离地高度导体的电晕放电特性及不同离地高度导体起始电晕电压的校正方法,在武汉超高压试验基地利用紫外成像仪进行了电晕试验。对JL/G1A-1250/100和JL/ gla -1250/70导体进行了不同接地高度的电晕试验。,单导体。分别对束距500mm的6束导体和束距550mm的8束导体进行测试。结果表明,在直流正电压下。,导线的起晕电压随离地高度的增加而增加。,不同的束距。不同束导体和单导体的电晕放电特性有一定差异;导线之间的起晕电压与不同束距的导线之间存在一定的函数关系。通过建立它们之间的函数关系。时,束导体的起晕电压可由单个导体的起晕电压值计算得到。,校正误差值可控制在13%以下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Corona Discharge Characteristics for Conductors of HVDC Transmission Lines with Different Heights to Groud
The corona discharge characteristic of the conductor is one of the key factors affecting the electromagnetic environment of the project. In order to obtain corona discharge characteristics of conductors with different heights to ground and correction methods for inception corona voltage of conductors with different heights to ground, corona test were carried out in Ultra-high Voltage Test Base in Wuhan with ultraviolet image apparatus. the corona test of conductors of JL/G1A-1250/100 and JL/G lA-1250/70 at different heights to ground were carried out., one single conductor., 6-bundle conductor with bundle space 500mm and 8-bundle conductor with bundle space 550mm were tested separately. The results show that Under DC positive voltage., the corona inception voltage for conductors increased with the rise of the height to ground., different bundle distances., different bundle conductors and one single conductor corona discharge characteristics have some differences; The corona inception voltage between single conductor and different bundle distances conductors have certain functional relationship. By establishing the functional relationship between them., the corona inception voltage of bundle conductors can be calculated by the corona inception voltage value of a single conductor., the value of correction errors can be controlled at less than 13%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信