多模态频率分析监测骨愈合

M. Nowak, M. N. Selamat, N. Baharin, W. Rahman
{"title":"多模态频率分析监测骨愈合","authors":"M. Nowak, M. N. Selamat, N. Baharin, W. Rahman","doi":"10.1109/NEBC.1991.154656","DOIUrl":null,"url":null,"abstract":"Multiple frequency modes were examined in an analogy of tibial bone healing. Wooden dowels were examined by striking with an instrumented hammer and monitoring an accelerometer at the other end of the rod. Three frequency modes were determined for intact rods, along with rods with partial transverse cuts (1/4, 1/2, 3/4 diameter depths). Fully cut rods were repaired with glue or foam to simulate complete and incomplete bone healing. The use of multiple frequency modes was determined to be a better predictor of cut bone than the first mode alone. Repaired rods displayed similar results. This work demonstrates the validity of frequency examination beyond simple first mode determination for the analysis of bone healing. Implications and future work are discussed.<<ETX>>","PeriodicalId":434209,"journal":{"name":"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multiple modal frequency analysis for monitoring of bone healing\",\"authors\":\"M. Nowak, M. N. Selamat, N. Baharin, W. Rahman\",\"doi\":\"10.1109/NEBC.1991.154656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multiple frequency modes were examined in an analogy of tibial bone healing. Wooden dowels were examined by striking with an instrumented hammer and monitoring an accelerometer at the other end of the rod. Three frequency modes were determined for intact rods, along with rods with partial transverse cuts (1/4, 1/2, 3/4 diameter depths). Fully cut rods were repaired with glue or foam to simulate complete and incomplete bone healing. The use of multiple frequency modes was determined to be a better predictor of cut bone than the first mode alone. Repaired rods displayed similar results. This work demonstrates the validity of frequency examination beyond simple first mode determination for the analysis of bone healing. Implications and future work are discussed.<<ETX>>\",\"PeriodicalId\":434209,\"journal\":{\"name\":\"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference\",\"volume\":\"130 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1991.154656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1991 IEEE Seventeenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1991.154656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在胫骨愈合的类比中检查了多个频率模式。用带仪器的锤子敲击木榫,并在木棒的另一端监测加速度计,从而检测木榫。三种频率模式确定了完整杆,以及部分横向切割杆(1/4,1/2,3/4直径深度)。用胶水或泡沫修复完全切割的骨棒,模拟完全和不完全的骨愈合。使用多种频率模式被确定为比单一的第一种模式更好的预测切骨。修复后的棒材也显示出类似的结果。这项工作证明了频率检查的有效性,而不是简单的第一模式确定分析骨愈合。讨论了影响和未来的工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multiple modal frequency analysis for monitoring of bone healing
Multiple frequency modes were examined in an analogy of tibial bone healing. Wooden dowels were examined by striking with an instrumented hammer and monitoring an accelerometer at the other end of the rod. Three frequency modes were determined for intact rods, along with rods with partial transverse cuts (1/4, 1/2, 3/4 diameter depths). Fully cut rods were repaired with glue or foam to simulate complete and incomplete bone healing. The use of multiple frequency modes was determined to be a better predictor of cut bone than the first mode alone. Repaired rods displayed similar results. This work demonstrates the validity of frequency examination beyond simple first mode determination for the analysis of bone healing. Implications and future work are discussed.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信