{"title":"起动电容式单相感应电动机带定时控制的电子起动器","authors":"Gancho Bojilov, Emil Rachev, V. Petrov","doi":"10.1109/SIELA54794.2022.9845752","DOIUrl":null,"url":null,"abstract":"This paper presents an inexpensive and reliable solution for control of the start-up process in a single-phase, capacitor-start capacitor-run induction motor. In general it is required to disconnect the starting capacitor at some point during ramp up of the motor. This could be dependent on the speed of the motor or a preset time. The solution in this paper is based on a triac as a power switch to turn off the capacitor, while the criterion for turn off is time based.","PeriodicalId":150282,"journal":{"name":"2022 22nd International Symposium on Electrical Apparatus and Technologies (SIELA)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electronic Starter with Timing Control for Start Capacitor Single Phase Induction Motor\",\"authors\":\"Gancho Bojilov, Emil Rachev, V. Petrov\",\"doi\":\"10.1109/SIELA54794.2022.9845752\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an inexpensive and reliable solution for control of the start-up process in a single-phase, capacitor-start capacitor-run induction motor. In general it is required to disconnect the starting capacitor at some point during ramp up of the motor. This could be dependent on the speed of the motor or a preset time. The solution in this paper is based on a triac as a power switch to turn off the capacitor, while the criterion for turn off is time based.\",\"PeriodicalId\":150282,\"journal\":{\"name\":\"2022 22nd International Symposium on Electrical Apparatus and Technologies (SIELA)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 22nd International Symposium on Electrical Apparatus and Technologies (SIELA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIELA54794.2022.9845752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 22nd International Symposium on Electrical Apparatus and Technologies (SIELA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIELA54794.2022.9845752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Electronic Starter with Timing Control for Start Capacitor Single Phase Induction Motor
This paper presents an inexpensive and reliable solution for control of the start-up process in a single-phase, capacitor-start capacitor-run induction motor. In general it is required to disconnect the starting capacitor at some point during ramp up of the motor. This could be dependent on the speed of the motor or a preset time. The solution in this paper is based on a triac as a power switch to turn off the capacitor, while the criterion for turn off is time based.