{"title":"基于克隆酶供体免疫分析技术的新型地高辛均相免疫分析的多中心评价结果。","authors":"J Jarausch,&nbsp;W Collinsworth,&nbsp;Y Cano,&nbsp;G Hafner,&nbsp;E Hammer,&nbsp;H Malandain,&nbsp;L Pokieser,&nbsp;F L Redondo,&nbsp;H Schlebusch,&nbsp;A Taylor","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A new CEDIA assay for the measurement of digoxin in serum on random access analyzers was evaluated by twelve laboratories in Europe and the United States. Studies on the analytical range, reproducibility, calibration stability, recovery in controls, interlaboratory comparability, comparability with routine methods, and the effect of various interfering factors have been performed and the results are presented in this paper. The analytical performance was comparable to that of routine methods provided the manual pipetting step for pre-incubation was performed with accurate pipettes. A major advantage of the CEDIA Digoxin assay in terms of convenience is the simple two-point calibration procedure. Moreover, digoxin can be determined within 15 minutes after receiving the samples on random access analyzers like Boehringer Mannheim/Hitachi analysis systems. Thus, the CEDIA Digoxin assay represents an attractive alternative to the measurement of digoxin on dedicated immunochemical assay systems.</p>","PeriodicalId":76822,"journal":{"name":"Wiener klinische Wochenschrift. Supplementum","volume":"191 ","pages":"69-73"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Results of the multicenter evaluation of a novel homogeneous immunoassay for digoxin based on the cloned enzyme donor immunoassay technology.\",\"authors\":\"J Jarausch,&nbsp;W Collinsworth,&nbsp;Y Cano,&nbsp;G Hafner,&nbsp;E Hammer,&nbsp;H Malandain,&nbsp;L Pokieser,&nbsp;F L Redondo,&nbsp;H Schlebusch,&nbsp;A Taylor\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A new CEDIA assay for the measurement of digoxin in serum on random access analyzers was evaluated by twelve laboratories in Europe and the United States. Studies on the analytical range, reproducibility, calibration stability, recovery in controls, interlaboratory comparability, comparability with routine methods, and the effect of various interfering factors have been performed and the results are presented in this paper. The analytical performance was comparable to that of routine methods provided the manual pipetting step for pre-incubation was performed with accurate pipettes. A major advantage of the CEDIA Digoxin assay in terms of convenience is the simple two-point calibration procedure. Moreover, digoxin can be determined within 15 minutes after receiving the samples on random access analyzers like Boehringer Mannheim/Hitachi analysis systems. Thus, the CEDIA Digoxin assay represents an attractive alternative to the measurement of digoxin on dedicated immunochemical assay systems.</p>\",\"PeriodicalId\":76822,\"journal\":{\"name\":\"Wiener klinische Wochenschrift. Supplementum\",\"volume\":\"191 \",\"pages\":\"69-73\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wiener klinische Wochenschrift. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wiener klinische Wochenschrift. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

欧洲和美国的12个实验室对一种新的CEDIA方法进行了评价,该方法可在随机进入分析仪上测量血清中地高辛的含量。对分析范围、重现性、校准稳定性、对照回收率、实验室间可比性、与常规方法的可比性以及各种干扰因素的影响进行了研究,并给出了结果。如果使用精确的移液器进行孵育前的手动移液步骤,则分析性能可与常规方法相媲美。CEDIA地高辛测定法在便利性方面的一个主要优势是简单的两点校准程序。此外,地高辛可以在收到随机访问分析仪(如勃林格曼海姆/日立分析系统)的样品后15分钟内确定。因此,CEDIA地高辛测定是在专用免疫化学测定系统上测量地高辛的一种有吸引力的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Results of the multicenter evaluation of a novel homogeneous immunoassay for digoxin based on the cloned enzyme donor immunoassay technology.

A new CEDIA assay for the measurement of digoxin in serum on random access analyzers was evaluated by twelve laboratories in Europe and the United States. Studies on the analytical range, reproducibility, calibration stability, recovery in controls, interlaboratory comparability, comparability with routine methods, and the effect of various interfering factors have been performed and the results are presented in this paper. The analytical performance was comparable to that of routine methods provided the manual pipetting step for pre-incubation was performed with accurate pipettes. A major advantage of the CEDIA Digoxin assay in terms of convenience is the simple two-point calibration procedure. Moreover, digoxin can be determined within 15 minutes after receiving the samples on random access analyzers like Boehringer Mannheim/Hitachi analysis systems. Thus, the CEDIA Digoxin assay represents an attractive alternative to the measurement of digoxin on dedicated immunochemical assay systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信