{"title":"小型负载调平系统专用双向DC/DC变换器电路结构","authors":"K. Hirachi, M. Yamanaka, K. Kajiyama, S. Isokane","doi":"10.1109/PCC.2002.997586","DOIUrl":null,"url":null,"abstract":"Small scale energy storage system incorporating a battery bank has attracted special interest as a promising load leveling system. Because battery bank voltage of this system is low, it is important to use a bidirectional chopper suitable for large step-up/step-down ratio. In this paper we propose a circuit topology of bidirectional chopper appropriate for small scale load leveling system and present the analytical and experimental results.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"63","resultStr":"{\"title\":\"Circuit configuration of bidirectional DC/DC converter specific for small scale load leveling system\",\"authors\":\"K. Hirachi, M. Yamanaka, K. Kajiyama, S. Isokane\",\"doi\":\"10.1109/PCC.2002.997586\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Small scale energy storage system incorporating a battery bank has attracted special interest as a promising load leveling system. Because battery bank voltage of this system is low, it is important to use a bidirectional chopper suitable for large step-up/step-down ratio. In this paper we propose a circuit topology of bidirectional chopper appropriate for small scale load leveling system and present the analytical and experimental results.\",\"PeriodicalId\":320424,\"journal\":{\"name\":\"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"63\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCC.2002.997586\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCC.2002.997586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Circuit configuration of bidirectional DC/DC converter specific for small scale load leveling system
Small scale energy storage system incorporating a battery bank has attracted special interest as a promising load leveling system. Because battery bank voltage of this system is low, it is important to use a bidirectional chopper suitable for large step-up/step-down ratio. In this paper we propose a circuit topology of bidirectional chopper appropriate for small scale load leveling system and present the analytical and experimental results.