旋转机械用富树脂绝缘系统固化过程中的介电响应

A. Helgeson, U. Gafvert
{"title":"旋转机械用富树脂绝缘系统固化过程中的介电响应","authors":"A. Helgeson, U. Gafvert","doi":"10.1109/CEIDP.1999.804646","DOIUrl":null,"url":null,"abstract":"Pre-impregnated (resin-rich) mica tape based insulation is used as electrical insulation in rotating machines. The dielectric properties of this system change drastically during the curing of the resin. We report on measurements of capacitance and loss, in the frequency range of 10 mHz to 1 MHz, on insulation models during the curing process. In order to relate the degree of curing to the dielectric response and to understand more about the curing reaction, differential scanning calorimetry (DSC) measurements were made. The parameters in a simple thermal activated model for the degree of cross-linking were estimated from DSC data. From shifting the dielectric data measured at different temperatures it is concluded that there are different activation energies for the uncured and the ready cured samples. Two simple equivalent circuit models are proposed to describe the dielectric behaviour. The conclusion is that dielectric response measurements can be used to monitor the curing process and evaluate the final degree of curing.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"425 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dielectric response during curing of a resin-rich insulation system for rotating machines\",\"authors\":\"A. Helgeson, U. Gafvert\",\"doi\":\"10.1109/CEIDP.1999.804646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pre-impregnated (resin-rich) mica tape based insulation is used as electrical insulation in rotating machines. The dielectric properties of this system change drastically during the curing of the resin. We report on measurements of capacitance and loss, in the frequency range of 10 mHz to 1 MHz, on insulation models during the curing process. In order to relate the degree of curing to the dielectric response and to understand more about the curing reaction, differential scanning calorimetry (DSC) measurements were made. The parameters in a simple thermal activated model for the degree of cross-linking were estimated from DSC data. From shifting the dielectric data measured at different temperatures it is concluded that there are different activation energies for the uncured and the ready cured samples. Two simple equivalent circuit models are proposed to describe the dielectric behaviour. The conclusion is that dielectric response measurements can be used to monitor the curing process and evaluate the final degree of curing.\",\"PeriodicalId\":267509,\"journal\":{\"name\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"volume\":\"425 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1999.804646\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.804646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

预浸渍(富树脂)云母带基绝缘用于旋转机械的电气绝缘。该体系的介电性能在树脂固化过程中发生了巨大的变化。我们报告了在固化过程中绝缘模型的电容和损耗的测量,频率范围为10 mHz至1 mHz。为了将固化程度与介质响应联系起来,并进一步了解固化反应,进行了差示扫描量热法(DSC)测量。用DSC数据估计了简单热激活模型中交联度的参数。通过对不同温度下测得的介电数据的变换,得出了未固化和已固化样品的活化能不同的结论。提出了两个简单的等效电路模型来描述介质的介电特性。结论是介质响应测量可以用来监测固化过程和评价最终的固化程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dielectric response during curing of a resin-rich insulation system for rotating machines
Pre-impregnated (resin-rich) mica tape based insulation is used as electrical insulation in rotating machines. The dielectric properties of this system change drastically during the curing of the resin. We report on measurements of capacitance and loss, in the frequency range of 10 mHz to 1 MHz, on insulation models during the curing process. In order to relate the degree of curing to the dielectric response and to understand more about the curing reaction, differential scanning calorimetry (DSC) measurements were made. The parameters in a simple thermal activated model for the degree of cross-linking were estimated from DSC data. From shifting the dielectric data measured at different temperatures it is concluded that there are different activation energies for the uncured and the ready cured samples. Two simple equivalent circuit models are proposed to describe the dielectric behaviour. The conclusion is that dielectric response measurements can be used to monitor the curing process and evaluate the final degree of curing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信