{"title":"低压空气、氩气和氦气中双绞线绝缘导体的局部放电测量","authors":"X. Liu, D. Kasten, S. Sebo","doi":"10.1109/ELINSL.2006.1665313","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) measurements in air, argon and helium, under pressures from 101.3 kPa (760 Torr) down to 0.27 kPa (2 Torr), have been performed for both 60 Hz AC and DC energization. The electrode arrangement is a twisted pair of insulated conductors taken from a standard aircraft wiring harness. The paper describes the physical PD test setup, the electrical connections for AC energization, and specifies the twisted pair arrangement of the insulated conductors. The results are presented in terms of PD current pulse waveforms and their analysis reflecting the effects of pressure and voltage","PeriodicalId":427638,"journal":{"name":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Partial discharge measurements for a twisted pair of insulated conductors at low pressures in air, argon and helium\",\"authors\":\"X. Liu, D. Kasten, S. Sebo\",\"doi\":\"10.1109/ELINSL.2006.1665313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge (PD) measurements in air, argon and helium, under pressures from 101.3 kPa (760 Torr) down to 0.27 kPa (2 Torr), have been performed for both 60 Hz AC and DC energization. The electrode arrangement is a twisted pair of insulated conductors taken from a standard aircraft wiring harness. The paper describes the physical PD test setup, the electrical connections for AC energization, and specifies the twisted pair arrangement of the insulated conductors. The results are presented in terms of PD current pulse waveforms and their analysis reflecting the effects of pressure and voltage\",\"PeriodicalId\":427638,\"journal\":{\"name\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"volume\":\"61 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2006.1665313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2006.1665313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Partial discharge measurements for a twisted pair of insulated conductors at low pressures in air, argon and helium
Partial discharge (PD) measurements in air, argon and helium, under pressures from 101.3 kPa (760 Torr) down to 0.27 kPa (2 Torr), have been performed for both 60 Hz AC and DC energization. The electrode arrangement is a twisted pair of insulated conductors taken from a standard aircraft wiring harness. The paper describes the physical PD test setup, the electrical connections for AC energization, and specifies the twisted pair arrangement of the insulated conductors. The results are presented in terms of PD current pulse waveforms and their analysis reflecting the effects of pressure and voltage