{"title":"使用脉冲传递时间连续监测血压的自适应算法","authors":"A. Jadooei, O. Zaderykhin, V. Shulgin","doi":"10.1109/ELNANO.2013.6552042","DOIUrl":null,"url":null,"abstract":"This paper attempts to present the problem of continuous Blood Pressure (BP) estimation using the Pulse Transit Time (PTT) cuff-less method. PTT is measured by synchronous electrocardiogram and photoplethysmograph (PPG) registration and the difference time is the basis parameter for blood pressure estimation. One of the problems to use PTT method is the necessity to calibrate with the traditional methods of Blood Pressure (TMBP) measurements. Adaptive Kalman filter (AKF) algorithm and maximum-likelihood estimation (MLE) methods were used in this paper to reduce the number of calibration measurements. The results clearly showed that the AKF used to estimate continuous BP, reduces the frequent use of the TMBP apparatus for calibration of BP measurement with PTT.","PeriodicalId":443634,"journal":{"name":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":"{\"title\":\"Adaptive algorithm for continuous monitoring of blood pressure using a pulse transit time\",\"authors\":\"A. Jadooei, O. Zaderykhin, V. Shulgin\",\"doi\":\"10.1109/ELNANO.2013.6552042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper attempts to present the problem of continuous Blood Pressure (BP) estimation using the Pulse Transit Time (PTT) cuff-less method. PTT is measured by synchronous electrocardiogram and photoplethysmograph (PPG) registration and the difference time is the basis parameter for blood pressure estimation. One of the problems to use PTT method is the necessity to calibrate with the traditional methods of Blood Pressure (TMBP) measurements. Adaptive Kalman filter (AKF) algorithm and maximum-likelihood estimation (MLE) methods were used in this paper to reduce the number of calibration measurements. The results clearly showed that the AKF used to estimate continuous BP, reduces the frequent use of the TMBP apparatus for calibration of BP measurement with PTT.\",\"PeriodicalId\":443634,\"journal\":{\"name\":\"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELNANO.2013.6552042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELNANO.2013.6552042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

摘要

本文试图提出使用无袖带脉搏传递时间(PTT)方法进行连续血压(BP)估计的问题。PTT是通过同步心电图和光电容积描记仪(PPG)配准来测量的,差值时间是估计血压的基础参数。使用PTT法的问题之一是必须与传统的血压测量方法进行校准。本文采用自适应卡尔曼滤波(AKF)算法和最大似然估计(MLE)方法来减少校准测量的次数。结果清楚地表明,AKF用于连续BP估计,减少了频繁使用TMBP仪器校准PTT BP测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptive algorithm for continuous monitoring of blood pressure using a pulse transit time
This paper attempts to present the problem of continuous Blood Pressure (BP) estimation using the Pulse Transit Time (PTT) cuff-less method. PTT is measured by synchronous electrocardiogram and photoplethysmograph (PPG) registration and the difference time is the basis parameter for blood pressure estimation. One of the problems to use PTT method is the necessity to calibrate with the traditional methods of Blood Pressure (TMBP) measurements. Adaptive Kalman filter (AKF) algorithm and maximum-likelihood estimation (MLE) methods were used in this paper to reduce the number of calibration measurements. The results clearly showed that the AKF used to estimate continuous BP, reduces the frequent use of the TMBP apparatus for calibration of BP measurement with PTT.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信