直流电力铁路牵引供电系统单调谐谐波无源滤波器设计

Jing En Chin, R. Tan, Jian Teck Hau
{"title":"直流电力铁路牵引供电系统单调谐谐波无源滤波器设计","authors":"Jing En Chin, R. Tan, Jian Teck Hau","doi":"10.1109/i-PACT52855.2021.9696916","DOIUrl":null,"url":null,"abstract":"The development of the electric railway system in Malaysia is growing rapidly since 1995. The use of a twelve-pulse rectifier to convert AC to DC supply in TPSS will generate the 11th and 13th harmonic current to the distribution lines. In this paper, a DC urban electric railway system is modeled and its harmonic analysis is discussed. It was found that the harmonic current distortion caused by the TPSS has exceeded the TDD and IHDi limits based on IEEE 519–2014 standard. Thus, the harmonic filter is chosen to mitigate this harmonic problem. The single-tuned harmonic passive filters are designed as they are more cost-effective, simple to design, and have high flexibility. The three-dimensional perspective of impedance, quality factor, and reactive power is analyzed to reduce the harmonic, improve the power factor, and prevent interharmonics at a low cost. The reactive power and quality factor selected based on the three-dimensional perspective are used to determine the capacitance, inductance, and resistance of the single-tuned harmonic passive filter. In addition, the graph of impedance against harmonic order and the bode diagram are plotted to analyze the characteristics of the filters. The results show that the designed filters can reduce the TDD to 1.97% and below. Besides, the 11th IHDi is reduced to 1.94% and below while the 13th IHDi is reduced to 1.97% and below. Therefore, the harmonic current distortion is complying with the IEEE 519-2014 standard limits with the presented single-tuned harmonic passive filters.","PeriodicalId":335956,"journal":{"name":"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)","volume":"355 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of Single-Tuned Harmonic Passive Filters for DC Electric Railway Traction Power Supply System\",\"authors\":\"Jing En Chin, R. Tan, Jian Teck Hau\",\"doi\":\"10.1109/i-PACT52855.2021.9696916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The development of the electric railway system in Malaysia is growing rapidly since 1995. The use of a twelve-pulse rectifier to convert AC to DC supply in TPSS will generate the 11th and 13th harmonic current to the distribution lines. In this paper, a DC urban electric railway system is modeled and its harmonic analysis is discussed. It was found that the harmonic current distortion caused by the TPSS has exceeded the TDD and IHDi limits based on IEEE 519–2014 standard. Thus, the harmonic filter is chosen to mitigate this harmonic problem. The single-tuned harmonic passive filters are designed as they are more cost-effective, simple to design, and have high flexibility. The three-dimensional perspective of impedance, quality factor, and reactive power is analyzed to reduce the harmonic, improve the power factor, and prevent interharmonics at a low cost. The reactive power and quality factor selected based on the three-dimensional perspective are used to determine the capacitance, inductance, and resistance of the single-tuned harmonic passive filter. In addition, the graph of impedance against harmonic order and the bode diagram are plotted to analyze the characteristics of the filters. The results show that the designed filters can reduce the TDD to 1.97% and below. Besides, the 11th IHDi is reduced to 1.94% and below while the 13th IHDi is reduced to 1.97% and below. Therefore, the harmonic current distortion is complying with the IEEE 519-2014 standard limits with the presented single-tuned harmonic passive filters.\",\"PeriodicalId\":335956,\"journal\":{\"name\":\"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)\",\"volume\":\"355 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/i-PACT52855.2021.9696916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/i-PACT52855.2021.9696916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

自1995年以来,马来西亚的电气化铁路系统发展迅速。在TPSS中使用十二脉冲整流器将交流电源转换为直流电源,将向配电线路产生第11和第13次谐波电流。本文对直流城市电气化轨道系统进行了建模,并对其谐波分析进行了讨论。结果表明,TPSS引起的谐波电流畸变已超过IEEE 519-2014标准的TDD和IHDi限值。因此,选择谐波滤波器来缓解这一谐波问题。单调谐谐波无源滤波器的设计更具成本效益,设计简单,灵活性高。从阻抗、质量因数和无功功率的三维角度进行分析,以低成本降低谐波,提高功率因数,防止间谐波的产生。利用三维视角选取的无功功率和品质因数来确定单调谐谐波无源滤波器的电容、电感和电阻。此外,还绘制了阻抗与谐波阶的关系图和波德图,分析了滤波器的特性。结果表明,所设计的滤波器可将TDD降低到1.97%及以下。此外,第11个IHDi降至1.94%及以下,第13个IHDi降至1.97%及以下。因此,所设计的单调谐谐波无源滤波器的谐波电流畸变符合IEEE 519-2014标准限值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Single-Tuned Harmonic Passive Filters for DC Electric Railway Traction Power Supply System
The development of the electric railway system in Malaysia is growing rapidly since 1995. The use of a twelve-pulse rectifier to convert AC to DC supply in TPSS will generate the 11th and 13th harmonic current to the distribution lines. In this paper, a DC urban electric railway system is modeled and its harmonic analysis is discussed. It was found that the harmonic current distortion caused by the TPSS has exceeded the TDD and IHDi limits based on IEEE 519–2014 standard. Thus, the harmonic filter is chosen to mitigate this harmonic problem. The single-tuned harmonic passive filters are designed as they are more cost-effective, simple to design, and have high flexibility. The three-dimensional perspective of impedance, quality factor, and reactive power is analyzed to reduce the harmonic, improve the power factor, and prevent interharmonics at a low cost. The reactive power and quality factor selected based on the three-dimensional perspective are used to determine the capacitance, inductance, and resistance of the single-tuned harmonic passive filter. In addition, the graph of impedance against harmonic order and the bode diagram are plotted to analyze the characteristics of the filters. The results show that the designed filters can reduce the TDD to 1.97% and below. Besides, the 11th IHDi is reduced to 1.94% and below while the 13th IHDi is reduced to 1.97% and below. Therefore, the harmonic current distortion is complying with the IEEE 519-2014 standard limits with the presented single-tuned harmonic passive filters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信