LVDC剩余电流的测量与检测算法研究

Zhimin Xie, Xingwen Li, Jing Wang, Silei Chen
{"title":"LVDC剩余电流的测量与检测算法研究","authors":"Zhimin Xie, Xingwen Li, Jing Wang, Silei Chen","doi":"10.1109/HLM49214.2020.9307908","DOIUrl":null,"url":null,"abstract":"With the rapid development of dc system, the residual current in dc system has become an urgent problem to be solved. However, the type B residual current devices (RCD) for ac systems could not be directly used in dc systems. The ac residual current caused by distributed capacitance and the rectifier seriously interferes with the accurate detection of the dc residual current. A detection simulation model of dc residual current based on magnetic modulation was established. The authors also proposed detection algorithms based on Kalman filter and moving average filter separately. The experimental results showed that the proposed model and detection algorithms were effective. They could detect the residual current in the dc system under ac interferences.","PeriodicalId":268345,"journal":{"name":"2020 IEEE 66th Holm Conference on Electrical Contacts and Intensive Course (HLM)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Study of Measurement and Detection Algorithm of LVDC Residual Current\",\"authors\":\"Zhimin Xie, Xingwen Li, Jing Wang, Silei Chen\",\"doi\":\"10.1109/HLM49214.2020.9307908\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the rapid development of dc system, the residual current in dc system has become an urgent problem to be solved. However, the type B residual current devices (RCD) for ac systems could not be directly used in dc systems. The ac residual current caused by distributed capacitance and the rectifier seriously interferes with the accurate detection of the dc residual current. A detection simulation model of dc residual current based on magnetic modulation was established. The authors also proposed detection algorithms based on Kalman filter and moving average filter separately. The experimental results showed that the proposed model and detection algorithms were effective. They could detect the residual current in the dc system under ac interferences.\",\"PeriodicalId\":268345,\"journal\":{\"name\":\"2020 IEEE 66th Holm Conference on Electrical Contacts and Intensive Course (HLM)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 66th Holm Conference on Electrical Contacts and Intensive Course (HLM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HLM49214.2020.9307908\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 66th Holm Conference on Electrical Contacts and Intensive Course (HLM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HLM49214.2020.9307908","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

随着直流系统的快速发展,直流系统的剩余电流已成为一个亟待解决的问题。然而,交流系统的B型剩余电流器件(RCD)不能直接用于直流系统。分布电容和整流器产生的交流剩余电流严重干扰了直流剩余电流的准确检测。建立了基于磁调制的直流剩余电流检测仿真模型。并分别提出了基于卡尔曼滤波和移动平均滤波的检测算法。实验结果表明,该模型和检测算法是有效的。他们可以检测直流系统在交流干扰下的剩余电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of Measurement and Detection Algorithm of LVDC Residual Current
With the rapid development of dc system, the residual current in dc system has become an urgent problem to be solved. However, the type B residual current devices (RCD) for ac systems could not be directly used in dc systems. The ac residual current caused by distributed capacitance and the rectifier seriously interferes with the accurate detection of the dc residual current. A detection simulation model of dc residual current based on magnetic modulation was established. The authors also proposed detection algorithms based on Kalman filter and moving average filter separately. The experimental results showed that the proposed model and detection algorithms were effective. They could detect the residual current in the dc system under ac interferences.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信