{"title":"降低混合直流连续换相故障风险的控制策略","authors":"Lin Zizhao, He Xiaofeng, Li Chengxiang, Yao Wenfeng, Xia Chengjun, Min Xin","doi":"10.1109/APPEEC45492.2019.8994490","DOIUrl":null,"url":null,"abstract":"The mechanism of continuous commutation failure of HVDC is analyzed and harmonic is considered to be one of the reasons for the continuous commutation failure of HVDC during restoration after AC fault. The harmonic voltage compensation component is added to the link to improve the reactive power support of the MMC-HVDC to the AC system during recovery. Thereby mitigate the risk of occurrence of continuous commutation failure. The effectiveness of the proposed control strategy is verified on PSCAD/EMTDC.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Control Strategy to Mitigate Risk of Hybrid HVDC Continuous Commutation Failure\",\"authors\":\"Lin Zizhao, He Xiaofeng, Li Chengxiang, Yao Wenfeng, Xia Chengjun, Min Xin\",\"doi\":\"10.1109/APPEEC45492.2019.8994490\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The mechanism of continuous commutation failure of HVDC is analyzed and harmonic is considered to be one of the reasons for the continuous commutation failure of HVDC during restoration after AC fault. The harmonic voltage compensation component is added to the link to improve the reactive power support of the MMC-HVDC to the AC system during recovery. Thereby mitigate the risk of occurrence of continuous commutation failure. The effectiveness of the proposed control strategy is verified on PSCAD/EMTDC.\",\"PeriodicalId\":241317,\"journal\":{\"name\":\"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC45492.2019.8994490\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC45492.2019.8994490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control Strategy to Mitigate Risk of Hybrid HVDC Continuous Commutation Failure
The mechanism of continuous commutation failure of HVDC is analyzed and harmonic is considered to be one of the reasons for the continuous commutation failure of HVDC during restoration after AC fault. The harmonic voltage compensation component is added to the link to improve the reactive power support of the MMC-HVDC to the AC system during recovery. Thereby mitigate the risk of occurrence of continuous commutation failure. The effectiveness of the proposed control strategy is verified on PSCAD/EMTDC.