D0螺线管核磁共振磁力仪

R. Yamada, S. Hansen, T. Kiper, J. Lofgren, T. Regan, R.P. Smith, G. Boero
{"title":"D0螺线管核磁共振磁力仪","authors":"R. Yamada, S. Hansen, T. Kiper, J. Lofgren, T. Regan, R.P. Smith, G. Boero","doi":"10.1109/NSSMIC.2002.1239382","DOIUrl":null,"url":null,"abstract":"A field monitoring system for the 2 Tesla solenoid of the D0 detector is described. It is comprised of a very small NMR probe cabled to a DSP based signal processing board. The design magnetic field range is from 1.0 to 2.2 Tesla, corresponding to an RF frequency range of 42.57 to 93.67 MHz. The desired accuracy is one part in 10/sup 5/. To minimize material in the interaction region of the D0 detector, the overall thickness of the NMR probe is 4 mm, including its mounting plate, and its width is 10 mm. To minimize cable mass, 4 mm diameter IMR-100A cables are used for transmitting the RF signals from a nearby patch panel 25 meters to each of four probes mounted within the bore of the solenoid. RG213U cables 45 meters long are used to send the RF from the D0 movable counting house to the patch panel. With this setup, the detector signal voltage at the movable counting house is in the range of 250-400 mV.","PeriodicalId":385259,"journal":{"name":"2002 IEEE Nuclear Science Symposium Conference Record","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The D0 solenoid NMR magnetometer\",\"authors\":\"R. Yamada, S. Hansen, T. Kiper, J. Lofgren, T. Regan, R.P. Smith, G. Boero\",\"doi\":\"10.1109/NSSMIC.2002.1239382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A field monitoring system for the 2 Tesla solenoid of the D0 detector is described. It is comprised of a very small NMR probe cabled to a DSP based signal processing board. The design magnetic field range is from 1.0 to 2.2 Tesla, corresponding to an RF frequency range of 42.57 to 93.67 MHz. The desired accuracy is one part in 10/sup 5/. To minimize material in the interaction region of the D0 detector, the overall thickness of the NMR probe is 4 mm, including its mounting plate, and its width is 10 mm. To minimize cable mass, 4 mm diameter IMR-100A cables are used for transmitting the RF signals from a nearby patch panel 25 meters to each of four probes mounted within the bore of the solenoid. RG213U cables 45 meters long are used to send the RF from the D0 movable counting house to the patch panel. With this setup, the detector signal voltage at the movable counting house is in the range of 250-400 mV.\",\"PeriodicalId\":385259,\"journal\":{\"name\":\"2002 IEEE Nuclear Science Symposium Conference Record\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 IEEE Nuclear Science Symposium Conference Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2002.1239382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Nuclear Science Symposium Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2002.1239382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种D0探测器2特斯拉螺线管的现场监测系统。它是由一个非常小的核磁共振探头电缆到一个基于DSP的信号处理板。设计磁场范围为1.0 ~ 2.2 Tesla,对应的射频频率范围为42.57 ~ 93.67 MHz。所要求的精度是1 / 10/sup /。为了最大限度地减少D0探测器相互作用区域内的物质,核磁共振探针的总厚度为4 mm,包括其安装板,其宽度为10 mm。为了尽量减少电缆质量,使用直径为4毫米的IMR-100A电缆将射频信号从附近25米的配线板传输到安装在螺线管孔内的四个探头中的每一个。RG213U电缆长度为45米,用于从D0移动计数室发送射频到配线板。通过这种设置,移动计数室的检测器信号电压在250-400 mV范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The D0 solenoid NMR magnetometer
A field monitoring system for the 2 Tesla solenoid of the D0 detector is described. It is comprised of a very small NMR probe cabled to a DSP based signal processing board. The design magnetic field range is from 1.0 to 2.2 Tesla, corresponding to an RF frequency range of 42.57 to 93.67 MHz. The desired accuracy is one part in 10/sup 5/. To minimize material in the interaction region of the D0 detector, the overall thickness of the NMR probe is 4 mm, including its mounting plate, and its width is 10 mm. To minimize cable mass, 4 mm diameter IMR-100A cables are used for transmitting the RF signals from a nearby patch panel 25 meters to each of four probes mounted within the bore of the solenoid. RG213U cables 45 meters long are used to send the RF from the D0 movable counting house to the patch panel. With this setup, the detector signal voltage at the movable counting house is in the range of 250-400 mV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信