{"title":"假脱落综合征患者与正常人假脱落性青光眼脉络膜厚度的比较","authors":"M. Tüfek, Nihat Aydın, C. Kara, Pinar Nalcacioglu","doi":"10.5336/ophthal.2019-72739","DOIUrl":null,"url":null,"abstract":"ABS TRACT Objektive: To compare the choroidal thickness in pseu- doexfoliation syndrome (PES) and pseudoexfoliative glaucoma (PEG) cases with healthy individuals. Material and Methods: We included 31 eyes of 31 patients with PES, 31 eyes of 31 patients with PEG, and 33 eyes of 33 healthy individuals in this study. All patients underwent choroidal thickness measurement at the subfoveal, nasal 500 µm, nasal 1000 µm, temporal 500 µm, and temporal 1000 µm areas by using the optical coherence tomography (3D OCT-2000, Topcon, Japan) device Results: There was no difference between the groups for gender and axial length (p>0.05). The subfoveal, nasal 500 µm and temporal 500 µm choroidal thickness values of the PEG cases were statistically sig- nificantly lower than the PES cases and the healthy group (p<0.05). Although the choroidal thickness values in the subfoveal and nasal 500 µm regions in the PES cases was lower than in the healthy group, this difference was not found to be statistically significant (p>0.05). Con- clusion: We found the subfoveal, nasal 500 µm and temporal 500 µm choroidal thickness to be significantly lower in the PEG cases than the other two groups. Choroidal thickness at the subfoveal and nasal 500 µm areas were also lower in the PES group than the control group but without statistical significance.","PeriodicalId":190073,"journal":{"name":"Turkiye Klinikleri Journal of Ophthalmology","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of Choroidal Thickness in Patients with Pseudoexfoliation Syndrome and Pseudoexfoliative Glaucomawith Normal Subjects\",\"authors\":\"M. Tüfek, Nihat Aydın, C. Kara, Pinar Nalcacioglu\",\"doi\":\"10.5336/ophthal.2019-72739\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABS TRACT Objektive: To compare the choroidal thickness in pseu- doexfoliation syndrome (PES) and pseudoexfoliative glaucoma (PEG) cases with healthy individuals. Material and Methods: We included 31 eyes of 31 patients with PES, 31 eyes of 31 patients with PEG, and 33 eyes of 33 healthy individuals in this study. All patients underwent choroidal thickness measurement at the subfoveal, nasal 500 µm, nasal 1000 µm, temporal 500 µm, and temporal 1000 µm areas by using the optical coherence tomography (3D OCT-2000, Topcon, Japan) device Results: There was no difference between the groups for gender and axial length (p>0.05). The subfoveal, nasal 500 µm and temporal 500 µm choroidal thickness values of the PEG cases were statistically sig- nificantly lower than the PES cases and the healthy group (p<0.05). Although the choroidal thickness values in the subfoveal and nasal 500 µm regions in the PES cases was lower than in the healthy group, this difference was not found to be statistically significant (p>0.05). Con- clusion: We found the subfoveal, nasal 500 µm and temporal 500 µm choroidal thickness to be significantly lower in the PEG cases than the other two groups. Choroidal thickness at the subfoveal and nasal 500 µm areas were also lower in the PES group than the control group but without statistical significance.\",\"PeriodicalId\":190073,\"journal\":{\"name\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5336/ophthal.2019-72739\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkiye Klinikleri Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5336/ophthal.2019-72739","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of Choroidal Thickness in Patients with Pseudoexfoliation Syndrome and Pseudoexfoliative Glaucomawith Normal Subjects
ABS TRACT Objektive: To compare the choroidal thickness in pseu- doexfoliation syndrome (PES) and pseudoexfoliative glaucoma (PEG) cases with healthy individuals. Material and Methods: We included 31 eyes of 31 patients with PES, 31 eyes of 31 patients with PEG, and 33 eyes of 33 healthy individuals in this study. All patients underwent choroidal thickness measurement at the subfoveal, nasal 500 µm, nasal 1000 µm, temporal 500 µm, and temporal 1000 µm areas by using the optical coherence tomography (3D OCT-2000, Topcon, Japan) device Results: There was no difference between the groups for gender and axial length (p>0.05). The subfoveal, nasal 500 µm and temporal 500 µm choroidal thickness values of the PEG cases were statistically sig- nificantly lower than the PES cases and the healthy group (p<0.05). Although the choroidal thickness values in the subfoveal and nasal 500 µm regions in the PES cases was lower than in the healthy group, this difference was not found to be statistically significant (p>0.05). Con- clusion: We found the subfoveal, nasal 500 µm and temporal 500 µm choroidal thickness to be significantly lower in the PEG cases than the other two groups. Choroidal thickness at the subfoveal and nasal 500 µm areas were also lower in the PES group than the control group but without statistical significance.