{"title":"基于改进MWFA的同步发电机偏心建模及空载电动势和电流谱故障特征评估","authors":"C. Bruzzese, A. Giordani, A. Rossi, E. Santini","doi":"10.1109/SPEEDHAM.2008.4581181","DOIUrl":null,"url":null,"abstract":"In this paper an accurate modeling of air-gap length function in polar and interpolar regions of non- isotropic synchronous generators is presented, for use in the MWFA (modified winding function approach), to obtain accurate machine simulations with eccentricities. Air-gap in interpolar regions is usually poorly modeled in current literature. Inductances obtained by the improved MWFA have been compared with 3D-FEM model obtained ones. External no-load e.m.f. and current spectra have been evaluated for a medium-power alternator with non-aligned rotor, and with various static and dynamic eccentricity degrees. Fault signatures appear all over the spectra, with variable entities, whose comprehensive evaluation can be used for fault severity assessment.","PeriodicalId":345557,"journal":{"name":"2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Synchronous generator eccentricities modeling by improved MWFA and fault signature evaluation in no-load E.M.F.s and current spectra\",\"authors\":\"C. Bruzzese, A. Giordani, A. Rossi, E. Santini\",\"doi\":\"10.1109/SPEEDHAM.2008.4581181\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper an accurate modeling of air-gap length function in polar and interpolar regions of non- isotropic synchronous generators is presented, for use in the MWFA (modified winding function approach), to obtain accurate machine simulations with eccentricities. Air-gap in interpolar regions is usually poorly modeled in current literature. Inductances obtained by the improved MWFA have been compared with 3D-FEM model obtained ones. External no-load e.m.f. and current spectra have been evaluated for a medium-power alternator with non-aligned rotor, and with various static and dynamic eccentricity degrees. Fault signatures appear all over the spectra, with variable entities, whose comprehensive evaluation can be used for fault severity assessment.\",\"PeriodicalId\":345557,\"journal\":{\"name\":\"2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEEDHAM.2008.4581181\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDHAM.2008.4581181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Synchronous generator eccentricities modeling by improved MWFA and fault signature evaluation in no-load E.M.F.s and current spectra
In this paper an accurate modeling of air-gap length function in polar and interpolar regions of non- isotropic synchronous generators is presented, for use in the MWFA (modified winding function approach), to obtain accurate machine simulations with eccentricities. Air-gap in interpolar regions is usually poorly modeled in current literature. Inductances obtained by the improved MWFA have been compared with 3D-FEM model obtained ones. External no-load e.m.f. and current spectra have been evaluated for a medium-power alternator with non-aligned rotor, and with various static and dynamic eccentricity degrees. Fault signatures appear all over the spectra, with variable entities, whose comprehensive evaluation can be used for fault severity assessment.