M J Koot, F N IJdenberg, R M Stuurman, J Poell, L J Bras, J J Langemeijer, L Lie-A-Huen
{"title":"冠状动脉旁路移植术患者静脉注射头孢呋辛后血清头孢呋辛浓度的高压液相色谱分析。","authors":"M J Koot, F N IJdenberg, R M Stuurman, J Poell, L J Bras, J J Langemeijer, L Lie-A-Huen","doi":"10.1007/BF01970173","DOIUrl":null,"url":null,"abstract":"<p><p>A simple reversed-phase high pressure liquid chromatographic method was developed for the determination of cefuroxime in the serum of patients undergoing coronary artery bypass grafting. The serum was cleaned up with a 3.3% solution of perchloric acid in water. Cefalexine was used as an internal standard. Detection was made by a UV multi-wavelength detector. The optimum wavelength for cefuroxime is 275 nm. The absolute recovery of this method was 90.9%; the limit of quantification was 0.7 mg/l. This analytical method was used in a study to investigate the cefuroxime serum concentration--time curves in 26 patients undergoing coronary artery bypass grafting. It was found that one single dose is sufficient to obtain effective serum concentrations.</p>","PeriodicalId":19804,"journal":{"name":"Pharmaceutisch weekblad. Scientific edition","volume":"14 6","pages":"360-4"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF01970173","citationCount":"11","resultStr":"{\"title\":\"High pressure liquid chromatographic analysis of the serum concentration of cefuroxime after an intravenous bolus injection of cefuroxime in patients with a coronary artery bypass grafting.\",\"authors\":\"M J Koot, F N IJdenberg, R M Stuurman, J Poell, L J Bras, J J Langemeijer, L Lie-A-Huen\",\"doi\":\"10.1007/BF01970173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A simple reversed-phase high pressure liquid chromatographic method was developed for the determination of cefuroxime in the serum of patients undergoing coronary artery bypass grafting. The serum was cleaned up with a 3.3% solution of perchloric acid in water. Cefalexine was used as an internal standard. Detection was made by a UV multi-wavelength detector. The optimum wavelength for cefuroxime is 275 nm. The absolute recovery of this method was 90.9%; the limit of quantification was 0.7 mg/l. This analytical method was used in a study to investigate the cefuroxime serum concentration--time curves in 26 patients undergoing coronary artery bypass grafting. It was found that one single dose is sufficient to obtain effective serum concentrations.</p>\",\"PeriodicalId\":19804,\"journal\":{\"name\":\"Pharmaceutisch weekblad. Scientific edition\",\"volume\":\"14 6\",\"pages\":\"360-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/BF01970173\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutisch weekblad. Scientific edition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/BF01970173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutisch weekblad. Scientific edition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF01970173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High pressure liquid chromatographic analysis of the serum concentration of cefuroxime after an intravenous bolus injection of cefuroxime in patients with a coronary artery bypass grafting.
A simple reversed-phase high pressure liquid chromatographic method was developed for the determination of cefuroxime in the serum of patients undergoing coronary artery bypass grafting. The serum was cleaned up with a 3.3% solution of perchloric acid in water. Cefalexine was used as an internal standard. Detection was made by a UV multi-wavelength detector. The optimum wavelength for cefuroxime is 275 nm. The absolute recovery of this method was 90.9%; the limit of quantification was 0.7 mg/l. This analytical method was used in a study to investigate the cefuroxime serum concentration--time curves in 26 patients undergoing coronary artery bypass grafting. It was found that one single dose is sufficient to obtain effective serum concentrations.