{"title":"u棒螺钉联合髂骨植骨直接修复青少年腰椎中裂症","authors":"Nian Zhou, Xin Lin, Xiaojun Zhang, Wei Jiang, Jieliang Shen, Xiuming Guo, Zhenming Hu, J. Hao","doi":"10.36076/pmcr.2021.5.347","DOIUrl":null,"url":null,"abstract":"Background: Spondylolysis is a bony defect of the pars interarticularis that most commonly occurs in the lower lumbar spine. However, the condition is rare in the mid-lumbar region. Here, we report on a new technique that involves the use of a U-rod and pedicle screw with iliac bone grafting for the direct intrasegmental repair of mid-lumbar spondylolysis in a teenager. Case Report: A 17-year-old male presented with complaints of mild low back pain after physical exercise, and the pain had aggravated in the last 3 months. Magnetic resonance imaging did not show compression of the intracanal neural tissue, and the lumbar discs did not demonstrate any obvious degeneration. He was diagnosed with L3 spondylolysis and lumbar sacralization. U-rod and screw construct with iliac bone grafting were used to directly repair the spondylolysis in L3. The low back pain totally disappeared 3 months after the surgery. A computerized tomography scan revealed the normal structure of L3 2 years post-surgically, and the internal fixation was removed 3 years later. Conclusions: This novel technique involving the use of a U-rod and pedicle screw associated with iliac bone grafting for the direct repair of mid-lumbar spondylolysis in the teenager yielded a satisfactory outcome, which was confirmed by favorable clinical and radiographic outcomes after 3 years. Key words: Mid-lumber spondylolysis, U-rod, direct repair","PeriodicalId":122753,"journal":{"name":"Pain Medicine Case Reports","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"U-Rod and Screw Construct Combined With Iliac Bone Grafting for Direct Repair of Teenager Mid-Lumbar Spondylolysis\",\"authors\":\"Nian Zhou, Xin Lin, Xiaojun Zhang, Wei Jiang, Jieliang Shen, Xiuming Guo, Zhenming Hu, J. Hao\",\"doi\":\"10.36076/pmcr.2021.5.347\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Spondylolysis is a bony defect of the pars interarticularis that most commonly occurs in the lower lumbar spine. However, the condition is rare in the mid-lumbar region. Here, we report on a new technique that involves the use of a U-rod and pedicle screw with iliac bone grafting for the direct intrasegmental repair of mid-lumbar spondylolysis in a teenager. Case Report: A 17-year-old male presented with complaints of mild low back pain after physical exercise, and the pain had aggravated in the last 3 months. Magnetic resonance imaging did not show compression of the intracanal neural tissue, and the lumbar discs did not demonstrate any obvious degeneration. He was diagnosed with L3 spondylolysis and lumbar sacralization. U-rod and screw construct with iliac bone grafting were used to directly repair the spondylolysis in L3. The low back pain totally disappeared 3 months after the surgery. A computerized tomography scan revealed the normal structure of L3 2 years post-surgically, and the internal fixation was removed 3 years later. Conclusions: This novel technique involving the use of a U-rod and pedicle screw associated with iliac bone grafting for the direct repair of mid-lumbar spondylolysis in the teenager yielded a satisfactory outcome, which was confirmed by favorable clinical and radiographic outcomes after 3 years. Key words: Mid-lumber spondylolysis, U-rod, direct repair\",\"PeriodicalId\":122753,\"journal\":{\"name\":\"Pain Medicine Case Reports\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pain Medicine Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36076/pmcr.2021.5.347\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pain Medicine Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36076/pmcr.2021.5.347","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:峡部裂是一种关节间部骨缺损,最常见于下腰椎。然而,这种情况在中腰椎区域很少见。在这里,我们报告了一种新技术,包括使用u棒和椎弓根螺钉结合髂骨植骨,直接在节段内修复青少年中腰椎峡部裂。病例报告:一名17岁男性,体育锻炼后出现轻度腰痛,近3个月疼痛加重。磁共振成像未见管内神经组织受压,腰椎间盘未见明显退变。他被诊断为L3峡部裂和腰椎骶骨化。采用u型棒螺钉结合髂骨植骨直接修复L3椎体峡部裂。术后3个月腰痛完全消失。术后2年计算机断层扫描显示L3结构正常,3年后取出内固定。结论:采用u型棒和椎弓根螺钉联合髂骨植骨直接修复青少年中腰椎峡部裂的新技术取得了令人满意的结果,3年后良好的临床和影像学结果证实了这一点。关键词:中腰椎峡部裂,u型棒,直接修复
本文章由计算机程序翻译,如有差异,请以英文原文为准。
U-Rod and Screw Construct Combined With Iliac Bone Grafting for Direct Repair of Teenager Mid-Lumbar Spondylolysis
Background: Spondylolysis is a bony defect of the pars interarticularis that most commonly occurs in the lower lumbar spine. However, the condition is rare in the mid-lumbar region. Here, we report on a new technique that involves the use of a U-rod and pedicle screw with iliac bone grafting for the direct intrasegmental repair of mid-lumbar spondylolysis in a teenager. Case Report: A 17-year-old male presented with complaints of mild low back pain after physical exercise, and the pain had aggravated in the last 3 months. Magnetic resonance imaging did not show compression of the intracanal neural tissue, and the lumbar discs did not demonstrate any obvious degeneration. He was diagnosed with L3 spondylolysis and lumbar sacralization. U-rod and screw construct with iliac bone grafting were used to directly repair the spondylolysis in L3. The low back pain totally disappeared 3 months after the surgery. A computerized tomography scan revealed the normal structure of L3 2 years post-surgically, and the internal fixation was removed 3 years later. Conclusions: This novel technique involving the use of a U-rod and pedicle screw associated with iliac bone grafting for the direct repair of mid-lumbar spondylolysis in the teenager yielded a satisfactory outcome, which was confirmed by favorable clinical and radiographic outcomes after 3 years. Key words: Mid-lumber spondylolysis, U-rod, direct repair
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信