{"title":"基于状态模型的永磁同步电机内部故障时域诊断——风力应用","authors":"A. Lalami, A. El-Ouafi, R. Wamkeue","doi":"10.1109/IRSEC.2013.6529652","DOIUrl":null,"url":null,"abstract":"Upon occurrence of an internal fault on the permanent magnet synchronous machine (PMSM), the topology of the stator is amended causing structural imbalances due to the change of the connection within the windings. In this work, a state model of internal faults of the PMSM is developed. This model is in the (abc) reference frame. The modeling approach is based on the assumption that each stator phase is replaced by two major and minor sub-windings. This model is used subsequently in the residual generation for diagnosis. The fault indicators are obtained by the projection in parity space and estimated using the Luenberger observer. A scenario of fault inter-turn by the short-circuit occurring between phase (a and b) is validated by simulation.","PeriodicalId":130577,"journal":{"name":"2013 International Renewable and Sustainable Energy Conference (IRSEC)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"State-model based time-domain diagnosis of internal faults for permanent magnet synchronous machine -wind application\",\"authors\":\"A. Lalami, A. El-Ouafi, R. Wamkeue\",\"doi\":\"10.1109/IRSEC.2013.6529652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Upon occurrence of an internal fault on the permanent magnet synchronous machine (PMSM), the topology of the stator is amended causing structural imbalances due to the change of the connection within the windings. In this work, a state model of internal faults of the PMSM is developed. This model is in the (abc) reference frame. The modeling approach is based on the assumption that each stator phase is replaced by two major and minor sub-windings. This model is used subsequently in the residual generation for diagnosis. The fault indicators are obtained by the projection in parity space and estimated using the Luenberger observer. A scenario of fault inter-turn by the short-circuit occurring between phase (a and b) is validated by simulation.\",\"PeriodicalId\":130577,\"journal\":{\"name\":\"2013 International Renewable and Sustainable Energy Conference (IRSEC)\",\"volume\":\"63 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Renewable and Sustainable Energy Conference (IRSEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRSEC.2013.6529652\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Renewable and Sustainable Energy Conference (IRSEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRSEC.2013.6529652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
State-model based time-domain diagnosis of internal faults for permanent magnet synchronous machine -wind application
Upon occurrence of an internal fault on the permanent magnet synchronous machine (PMSM), the topology of the stator is amended causing structural imbalances due to the change of the connection within the windings. In this work, a state model of internal faults of the PMSM is developed. This model is in the (abc) reference frame. The modeling approach is based on the assumption that each stator phase is replaced by two major and minor sub-windings. This model is used subsequently in the residual generation for diagnosis. The fault indicators are obtained by the projection in parity space and estimated using the Luenberger observer. A scenario of fault inter-turn by the short-circuit occurring between phase (a and b) is validated by simulation.