{"title":"用于高压应用的安全可靠的温度和压力测量","authors":"T. Maupin, J. Breunig","doi":"10.1115/pvp2019-93850","DOIUrl":null,"url":null,"abstract":"\n For high pressure polyethylene applications, reliable temperature and pressure measurement with extremely fast response time, is crucial in order to avoid decomposition. Furthermore instrumentation must withstand not only the high pressures and temperatures, but also the vibration present in such a challenging environment. The requirements of temperature and pressure instrumentation include high quality mineral insulated cable, production techniques such as vacuum brazing and thin film sputtering as well as testing facilities. With this information, operators will be able to select high pressure thermocouples and pressure transmitters which are specifically designed for their application.","PeriodicalId":174920,"journal":{"name":"Volume 5: High-Pressure Technology; Rudy Scavuzzo Student Paper Symposium and 27th Annual Student Paper Competition; ASME Nondestructive Evaluation, Diagnosis and Prognosis Division (NDPD)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safe and Reliable Temperature and Pressure Measurement for High Pressure Applications\",\"authors\":\"T. Maupin, J. Breunig\",\"doi\":\"10.1115/pvp2019-93850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n For high pressure polyethylene applications, reliable temperature and pressure measurement with extremely fast response time, is crucial in order to avoid decomposition. Furthermore instrumentation must withstand not only the high pressures and temperatures, but also the vibration present in such a challenging environment. The requirements of temperature and pressure instrumentation include high quality mineral insulated cable, production techniques such as vacuum brazing and thin film sputtering as well as testing facilities. With this information, operators will be able to select high pressure thermocouples and pressure transmitters which are specifically designed for their application.\",\"PeriodicalId\":174920,\"journal\":{\"name\":\"Volume 5: High-Pressure Technology; Rudy Scavuzzo Student Paper Symposium and 27th Annual Student Paper Competition; ASME Nondestructive Evaluation, Diagnosis and Prognosis Division (NDPD)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 5: High-Pressure Technology; Rudy Scavuzzo Student Paper Symposium and 27th Annual Student Paper Competition; ASME Nondestructive Evaluation, Diagnosis and Prognosis Division (NDPD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/pvp2019-93850\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 5: High-Pressure Technology; Rudy Scavuzzo Student Paper Symposium and 27th Annual Student Paper Competition; ASME Nondestructive Evaluation, Diagnosis and Prognosis Division (NDPD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/pvp2019-93850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Safe and Reliable Temperature and Pressure Measurement for High Pressure Applications
For high pressure polyethylene applications, reliable temperature and pressure measurement with extremely fast response time, is crucial in order to avoid decomposition. Furthermore instrumentation must withstand not only the high pressures and temperatures, but also the vibration present in such a challenging environment. The requirements of temperature and pressure instrumentation include high quality mineral insulated cable, production techniques such as vacuum brazing and thin film sputtering as well as testing facilities. With this information, operators will be able to select high pressure thermocouples and pressure transmitters which are specifically designed for their application.