基于电极有限维模型的三极同心环电极拉普拉斯估计精度的综合优化

O. Makeyev
{"title":"基于电极有限维模型的三极同心环电极拉普拉斯估计精度的综合优化","authors":"O. Makeyev","doi":"10.3390/ecsa-7-08167","DOIUrl":null,"url":null,"abstract":"Optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model widely used in the past. This makes the optimization problem comprehensive since all of the electrode parameters, including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation since the ability to estimate the Laplacian at each electrode constitutes the primary biomedical significance of concentric ring electrodes. Even though the obtained results and derived principles defining optimal electrode configurations are illustrated on tripolar (two concentric rings) electrodes, they were also confirmed for quadripolar (three rings) and pentapolar (four rings) electrodes and are likely to continue to hold for any higher number of concentric rings. For tripolar concentric ring electrodes, the optimal configuration was compared to previously proposed, linearly increasing inter-ring distances and constant inter-ring distances in configurations of the same size and based on the same finite dimensions model of the electrode. The obtained results suggest that previously proposed configurations correspond to almost two-fold and more than three-fold increases in Laplacian estimation error, respectively, compared to the optimal configuration proposed in this study.","PeriodicalId":270652,"journal":{"name":"Proceedings of 7th International Electronic Conference on Sensors and Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comprehensive optimization of the tripolar concentric ring electrode with respect to the accuracy of Laplacian estimation based on the finite dimensions model of the electrode\",\"authors\":\"O. Makeyev\",\"doi\":\"10.3390/ecsa-7-08167\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model widely used in the past. This makes the optimization problem comprehensive since all of the electrode parameters, including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation since the ability to estimate the Laplacian at each electrode constitutes the primary biomedical significance of concentric ring electrodes. Even though the obtained results and derived principles defining optimal electrode configurations are illustrated on tripolar (two concentric rings) electrodes, they were also confirmed for quadripolar (three rings) and pentapolar (four rings) electrodes and are likely to continue to hold for any higher number of concentric rings. For tripolar concentric ring electrodes, the optimal configuration was compared to previously proposed, linearly increasing inter-ring distances and constant inter-ring distances in configurations of the same size and based on the same finite dimensions model of the electrode. The obtained results suggest that previously proposed configurations correspond to almost two-fold and more than three-fold increases in Laplacian estimation error, respectively, compared to the optimal configuration proposed in this study.\",\"PeriodicalId\":270652,\"journal\":{\"name\":\"Proceedings of 7th International Electronic Conference on Sensors and Applications\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 7th International Electronic Conference on Sensors and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/ecsa-7-08167\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 7th International Electronic Conference on Sensors and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/ecsa-7-08167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在本研究中进行的优化是基于同心环电极的有限尺寸模型,而不是过去广泛使用的可忽略尺寸模型。这使得优化问题全面,因为所有电极参数,包括中心圆盘的半径和同心圆的单个宽度,首次同时优化。使用的优化准则是最大化表面拉普拉斯估计的准确性,因为估计每个电极上的拉普拉斯量的能力构成了同心环电极的主要生物医学意义。尽管所获得的结果和推导出的定义最佳电极配置的原理是在三极性(两个同心环)电极上说明的,但它们也被证实适用于四极性(三个环)和五极性(四个环)电极,并且可能继续适用于更多数量的同心环。对于三极性同心环电极,比较了先前提出的最优配置,即在相同尺寸和基于相同电极有限尺寸模型的配置下,线性增加环间距离和保持环间距离。所得结果表明,与本研究提出的最优配置相比,先前提出的配置对应的拉普拉斯估计误差分别增加了近两倍和三倍以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comprehensive optimization of the tripolar concentric ring electrode with respect to the accuracy of Laplacian estimation based on the finite dimensions model of the electrode
Optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model widely used in the past. This makes the optimization problem comprehensive since all of the electrode parameters, including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation since the ability to estimate the Laplacian at each electrode constitutes the primary biomedical significance of concentric ring electrodes. Even though the obtained results and derived principles defining optimal electrode configurations are illustrated on tripolar (two concentric rings) electrodes, they were also confirmed for quadripolar (three rings) and pentapolar (four rings) electrodes and are likely to continue to hold for any higher number of concentric rings. For tripolar concentric ring electrodes, the optimal configuration was compared to previously proposed, linearly increasing inter-ring distances and constant inter-ring distances in configurations of the same size and based on the same finite dimensions model of the electrode. The obtained results suggest that previously proposed configurations correspond to almost two-fold and more than three-fold increases in Laplacian estimation error, respectively, compared to the optimal configuration proposed in this study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信