B. Kazimierczak, A. Baraniecka, D. Pijanowska, M. Dawgul, J. Kruk, Alfred Krzyskow, W. Torbicz
{"title":"电位传感器中的免疫反应","authors":"B. Kazimierczak, A. Baraniecka, D. Pijanowska, M. Dawgul, J. Kruk, Alfred Krzyskow, W. Torbicz","doi":"10.1117/12.475982","DOIUrl":null,"url":null,"abstract":"This paper presents results concerning the optimization of the measuring system of ImFET model based on the ISFET and ELISA test scheme. In the developed model of the ImFET we obtained linear changes of pH as a function of logarithm of antibodies concentration.","PeriodicalId":156625,"journal":{"name":"Systems of Optical Security","volume":"92 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Immunoreactions in potentiometric sensors\",\"authors\":\"B. Kazimierczak, A. Baraniecka, D. Pijanowska, M. Dawgul, J. Kruk, Alfred Krzyskow, W. Torbicz\",\"doi\":\"10.1117/12.475982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents results concerning the optimization of the measuring system of ImFET model based on the ISFET and ELISA test scheme. In the developed model of the ImFET we obtained linear changes of pH as a function of logarithm of antibodies concentration.\",\"PeriodicalId\":156625,\"journal\":{\"name\":\"Systems of Optical Security\",\"volume\":\"92 4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Systems of Optical Security\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.475982\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Systems of Optical Security","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.475982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
This paper presents results concerning the optimization of the measuring system of ImFET model based on the ISFET and ELISA test scheme. In the developed model of the ImFET we obtained linear changes of pH as a function of logarithm of antibodies concentration.