全肠外营养输液中微量元素相容性的评价。

M C Allwood, M Greenwood
{"title":"全肠外营养输液中微量元素相容性的评价。","authors":"M C Allwood,&nbsp;M Greenwood","doi":"10.1007/BF01977621","DOIUrl":null,"url":null,"abstract":"<p><p>The application of X-ray energy dispersive spectroscopy to detect elements collected from TPN mixtures on membrane filters has been investigated. Many simple total parenteral nutrition mixtures prepared aseptically in large bags can be stored for extended periods. Trace elements are normally excluded from such bags, because not enough is known about their long-term stability and compatibility in total parenteral nutrition mixtures. Assessing the compatibility of many trace elements by conventional methods that rely on detecting concentration changes is extremely difficult. Analysis of precipitates from total parenteral nutrition mixtures confirmed that the proposed method was capable of identifying a number of elements from the mixture in complex precipitates, including calcium, phosphorus, iron, copper and selenium.</p>","PeriodicalId":19804,"journal":{"name":"Pharmaceutisch weekblad. Scientific edition","volume":"14 5","pages":"321-4"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF01977621","citationCount":"7","resultStr":"{\"title\":\"Assessment of trace element compatibility in total parenteral nutrition infusions.\",\"authors\":\"M C Allwood,&nbsp;M Greenwood\",\"doi\":\"10.1007/BF01977621\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The application of X-ray energy dispersive spectroscopy to detect elements collected from TPN mixtures on membrane filters has been investigated. Many simple total parenteral nutrition mixtures prepared aseptically in large bags can be stored for extended periods. Trace elements are normally excluded from such bags, because not enough is known about their long-term stability and compatibility in total parenteral nutrition mixtures. Assessing the compatibility of many trace elements by conventional methods that rely on detecting concentration changes is extremely difficult. Analysis of precipitates from total parenteral nutrition mixtures confirmed that the proposed method was capable of identifying a number of elements from the mixture in complex precipitates, including calcium, phosphorus, iron, copper and selenium.</p>\",\"PeriodicalId\":19804,\"journal\":{\"name\":\"Pharmaceutisch weekblad. Scientific edition\",\"volume\":\"14 5\",\"pages\":\"321-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/BF01977621\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutisch weekblad. Scientific edition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/BF01977621\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutisch weekblad. Scientific edition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF01977621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

研究了x射线能量色散光谱在膜过滤器上检测TPN混合物中所收集元素的应用。许多简单的全肠外营养混合物在大袋子中无菌制备,可以长期储存。微量元素通常被排除在这样的袋子之外,因为对它们在全肠外营养混合物中的长期稳定性和相容性知之甚少。通过依赖于检测浓度变化的传统方法来评估许多微量元素的相容性是非常困难的。对全肠外营养混合物的沉淀物的分析证实,所提出的方法能够从复杂沉淀物的混合物中识别出许多元素,包括钙、磷、铁、铜和硒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of trace element compatibility in total parenteral nutrition infusions.

The application of X-ray energy dispersive spectroscopy to detect elements collected from TPN mixtures on membrane filters has been investigated. Many simple total parenteral nutrition mixtures prepared aseptically in large bags can be stored for extended periods. Trace elements are normally excluded from such bags, because not enough is known about their long-term stability and compatibility in total parenteral nutrition mixtures. Assessing the compatibility of many trace elements by conventional methods that rely on detecting concentration changes is extremely difficult. Analysis of precipitates from total parenteral nutrition mixtures confirmed that the proposed method was capable of identifying a number of elements from the mixture in complex precipitates, including calcium, phosphorus, iron, copper and selenium.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信