在BMI应用中,通过对运动皮质活动的频率解码来估计两指握力类型和握力水平

M. Tagliabue, N. Francis, Yaoyao Hao, Margaux Duret, T. Brochier, A. Riehle, M. Maier, S. Eskiizmirliler
{"title":"在BMI应用中,通过对运动皮质活动的频率解码来估计两指握力类型和握力水平","authors":"M. Tagliabue, N. Francis, Yaoyao Hao, Margaux Duret, T. Brochier, A. Riehle, M. Maier, S. Eskiizmirliler","doi":"10.1109/ICAR.2015.7251473","DOIUrl":null,"url":null,"abstract":"This study focuses on the estimation of kinematic and kinetic information during two-digit grasping using frequency decoding of motor cortex spike trains for brain machine interface applications. Neural data were recorded by a 100-microelectrode array implanted in the motor cortex of one monkey performing instructed reach-grasp-and-pull movements. Decoding of neural data was performed by two different algorithms: i) through Artificial Neural Networks (ANN) consisting of a multi layer perceptron (MLP), and ii) by a Support Vector Machine (SVM) with linear kernel function. Decoding aimed at classifying the upcoming grip type (precision grip vs. side grip) as well as the required grip force (low vs. high). We then used the decoded information to reproduce the monkey's movement on a robotic platform consisting of a two-finger, eleven degrees of freedom (DoF) robotic hand carried by a six DoF robotic arm. The results show that 1) in terms of performance there was no significant difference between ANN and SVM prediction. Both algorithms can be used for frequency decoding of multiple motor cortex spike trains: good performance was found for grip type prediction, less so for grip force. 2) For both algorithms the prediction error was significantly dependent on the position of the input time window associated to different stages of the instructed grasp movement. 3) The lower performance of grasp force prediction was improved by optimizing the neuronal population size presented to the ANN input layer on the basis of information redundancy.","PeriodicalId":432004,"journal":{"name":"2015 International Conference on Advanced Robotics (ICAR)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Estimation of two-digit grip type and grip force level by frequency decoding of motor cortex activity for a BMI application\",\"authors\":\"M. Tagliabue, N. Francis, Yaoyao Hao, Margaux Duret, T. Brochier, A. Riehle, M. Maier, S. Eskiizmirliler\",\"doi\":\"10.1109/ICAR.2015.7251473\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study focuses on the estimation of kinematic and kinetic information during two-digit grasping using frequency decoding of motor cortex spike trains for brain machine interface applications. Neural data were recorded by a 100-microelectrode array implanted in the motor cortex of one monkey performing instructed reach-grasp-and-pull movements. Decoding of neural data was performed by two different algorithms: i) through Artificial Neural Networks (ANN) consisting of a multi layer perceptron (MLP), and ii) by a Support Vector Machine (SVM) with linear kernel function. Decoding aimed at classifying the upcoming grip type (precision grip vs. side grip) as well as the required grip force (low vs. high). We then used the decoded information to reproduce the monkey's movement on a robotic platform consisting of a two-finger, eleven degrees of freedom (DoF) robotic hand carried by a six DoF robotic arm. The results show that 1) in terms of performance there was no significant difference between ANN and SVM prediction. Both algorithms can be used for frequency decoding of multiple motor cortex spike trains: good performance was found for grip type prediction, less so for grip force. 2) For both algorithms the prediction error was significantly dependent on the position of the input time window associated to different stages of the instructed grasp movement. 3) The lower performance of grasp force prediction was improved by optimizing the neuronal population size presented to the ANN input layer on the basis of information redundancy.\",\"PeriodicalId\":432004,\"journal\":{\"name\":\"2015 International Conference on Advanced Robotics (ICAR)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Advanced Robotics (ICAR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAR.2015.7251473\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Advanced Robotics (ICAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAR.2015.7251473","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究的重点是在脑机接口应用中,利用运动皮质脉冲序列的频率解码来估计两位数抓取过程中的运动学和动力学信息。神经数据通过植入一只猴子的运动皮层的100微电极阵列被记录下来。神经数据的解码由两种不同的算法完成:i)通过由多层感知器(MLP)组成的人工神经网络(ANN), ii)通过具有线性核函数的支持向量机(SVM)。解码旨在分类即将到来的握把类型(精确握把vs侧握把)以及所需的握把力(低vs高)。然后,我们使用解码的信息在一个机器人平台上重现了猴子的运动,这个机器人平台由一个六自由度机械臂携带的两根手指,十一自由度(DoF)机械手组成。结果表明:1)在性能方面,人工神经网络与支持向量机预测没有显著差异。两种算法均可用于多个运动皮质脉冲序列的频率解码:握力类型预测效果较好,握力预测效果较差。2)两种算法的预测误差显著依赖于指令抓取运动不同阶段相关的输入时间窗的位置。3)在信息冗余的基础上,通过优化神经网络输入层的神经元种群大小,改善了抓取力预测的较差性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimation of two-digit grip type and grip force level by frequency decoding of motor cortex activity for a BMI application
This study focuses on the estimation of kinematic and kinetic information during two-digit grasping using frequency decoding of motor cortex spike trains for brain machine interface applications. Neural data were recorded by a 100-microelectrode array implanted in the motor cortex of one monkey performing instructed reach-grasp-and-pull movements. Decoding of neural data was performed by two different algorithms: i) through Artificial Neural Networks (ANN) consisting of a multi layer perceptron (MLP), and ii) by a Support Vector Machine (SVM) with linear kernel function. Decoding aimed at classifying the upcoming grip type (precision grip vs. side grip) as well as the required grip force (low vs. high). We then used the decoded information to reproduce the monkey's movement on a robotic platform consisting of a two-finger, eleven degrees of freedom (DoF) robotic hand carried by a six DoF robotic arm. The results show that 1) in terms of performance there was no significant difference between ANN and SVM prediction. Both algorithms can be used for frequency decoding of multiple motor cortex spike trains: good performance was found for grip type prediction, less so for grip force. 2) For both algorithms the prediction error was significantly dependent on the position of the input time window associated to different stages of the instructed grasp movement. 3) The lower performance of grasp force prediction was improved by optimizing the neuronal population size presented to the ANN input layer on the basis of information redundancy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信