M. Moon, Changhee Lee, V. Em, H. Kang, U. Nam, A. Gabriel
{"title":"用于残余应力测量的高光度位置灵敏中子探测器","authors":"M. Moon, Changhee Lee, V. Em, H. Kang, U. Nam, A. Gabriel","doi":"10.1109/NSSMIC.2001.1008463","DOIUrl":null,"url":null,"abstract":"Because the diffraction angle is equal or close to 90/spl deg/ in residual stress measurements by neutron diffraction, the luminosity of the device can be increased by expansion of the detection window height without deformation of the diffraction peak. A high luminosity position sensitive neutron detector has been designed and fabricated for measuring residual stress. The detector has a working window of 200 /spl times/ 100 mm/sup 2/. The detector has high efficiency, good position resolution and linearity, small position error and low background counts. The results of the detector characteristics are presented.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"A high luminosity position sensitive neutron detector for residual stress measurements\",\"authors\":\"M. Moon, Changhee Lee, V. Em, H. Kang, U. Nam, A. Gabriel\",\"doi\":\"10.1109/NSSMIC.2001.1008463\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Because the diffraction angle is equal or close to 90/spl deg/ in residual stress measurements by neutron diffraction, the luminosity of the device can be increased by expansion of the detection window height without deformation of the diffraction peak. A high luminosity position sensitive neutron detector has been designed and fabricated for measuring residual stress. The detector has a working window of 200 /spl times/ 100 mm/sup 2/. The detector has high efficiency, good position resolution and linearity, small position error and low background counts. The results of the detector characteristics are presented.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1008463\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A high luminosity position sensitive neutron detector for residual stress measurements
Because the diffraction angle is equal or close to 90/spl deg/ in residual stress measurements by neutron diffraction, the luminosity of the device can be increased by expansion of the detection window height without deformation of the diffraction peak. A high luminosity position sensitive neutron detector has been designed and fabricated for measuring residual stress. The detector has a working window of 200 /spl times/ 100 mm/sup 2/. The detector has high efficiency, good position resolution and linearity, small position error and low background counts. The results of the detector characteristics are presented.