使用氧多丝表面电极直接测量不同吸入氧浓度下肺泡PO2的分布。

J Höper, L Plasswilm
{"title":"使用氧多丝表面电极直接测量不同吸入氧浓度下肺泡PO2的分布。","authors":"J Höper,&nbsp;L Plasswilm","doi":"10.1088/0143-0815/13/3/006","DOIUrl":null,"url":null,"abstract":"<p><p>Experiments were performed in six anaesthetised, mechanically ventilated rabbits. After thoracotomy, a multiwire surface PO2 electrode was placed at the pleural surface by means of a special holder. The local distribution of PO2 was investigated at different values of inspired oxygen concentration (FIO2). The data were analysed in order to establish (a) whether the PO2 values measured at the lung surface reflect intra-alveolar PO2 and (b) that the distribution of these values represent real physiological differences between alveoli. The mean PO2 values were related to the calculated mean alveolar PO2 (PAO2) values (r = 0.97) indicating that it is possible to study PAO2 by local measurements. It can therefore be concluded that the technique used allows the study of the influence of different FIO2 values on the distribution of PAO2. Each local PAO2 value is the result of the corresponding local ventilation/perfusion ratio (VA/Q) therefore the distribution of PAO2 values represents the distribution of VA/Q. An increasing FIO2 causes an increasing heterogeneity of PAO2 and thus VA/Q leading to a concomitant increase in the alveolo-arterial oxygen difference. At the moment it is not possible to decide if this heterogeneity is primarily caused by heterogeneities in perfusion or ventilation. The results could throw fresh light on the effect of different ventilation procedures.</p>","PeriodicalId":77070,"journal":{"name":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","volume":"13 3","pages":"263-71"},"PeriodicalIF":0.0000,"publicationDate":"1992-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0143-0815/13/3/006","citationCount":"4","resultStr":"{\"title\":\"Use of an oxygen multiwire surface electrode for the direct measurement of the distribution of alveolar PO2 at different inspired oxygen concentrations.\",\"authors\":\"J Höper,&nbsp;L Plasswilm\",\"doi\":\"10.1088/0143-0815/13/3/006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Experiments were performed in six anaesthetised, mechanically ventilated rabbits. After thoracotomy, a multiwire surface PO2 electrode was placed at the pleural surface by means of a special holder. The local distribution of PO2 was investigated at different values of inspired oxygen concentration (FIO2). The data were analysed in order to establish (a) whether the PO2 values measured at the lung surface reflect intra-alveolar PO2 and (b) that the distribution of these values represent real physiological differences between alveoli. The mean PO2 values were related to the calculated mean alveolar PO2 (PAO2) values (r = 0.97) indicating that it is possible to study PAO2 by local measurements. It can therefore be concluded that the technique used allows the study of the influence of different FIO2 values on the distribution of PAO2. Each local PAO2 value is the result of the corresponding local ventilation/perfusion ratio (VA/Q) therefore the distribution of PAO2 values represents the distribution of VA/Q. An increasing FIO2 causes an increasing heterogeneity of PAO2 and thus VA/Q leading to a concomitant increase in the alveolo-arterial oxygen difference. At the moment it is not possible to decide if this heterogeneity is primarily caused by heterogeneities in perfusion or ventilation. The results could throw fresh light on the effect of different ventilation procedures.</p>\",\"PeriodicalId\":77070,\"journal\":{\"name\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"volume\":\"13 3\",\"pages\":\"263-71\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1088/0143-0815/13/3/006\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0143-0815/13/3/006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0143-0815/13/3/006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

实验在6只麻醉、机械通气的家兔身上进行。开胸后,在胸膜表面放置多丝表面PO2电极。研究了不同吸入氧浓度(FIO2)下PO2的局部分布。对数据进行分析是为了确定(a)肺表面测量的PO2值是否反映肺泡内PO2,以及(b)这些值的分布是否代表肺泡之间的真实生理差异。平均PO2值与计算的平均肺泡PO2 (PAO2)值相关(r = 0.97),表明可以通过局部测量来研究PAO2。因此可以得出结论,所使用的技术允许研究不同FIO2值对PAO2分布的影响。每个局部PAO2值是相应局部通气/灌注比(VA/Q)的结果,因此PAO2值的分布代表VA/Q的分布。FIO2的增加导致PAO2的异质性增加,因此VA/Q导致肺泡-动脉氧差随之增加。目前还无法确定这种异质性主要是由灌注或通气的异质性引起的。研究结果为不同通风方式的影响提供了新的思路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of an oxygen multiwire surface electrode for the direct measurement of the distribution of alveolar PO2 at different inspired oxygen concentrations.

Experiments were performed in six anaesthetised, mechanically ventilated rabbits. After thoracotomy, a multiwire surface PO2 electrode was placed at the pleural surface by means of a special holder. The local distribution of PO2 was investigated at different values of inspired oxygen concentration (FIO2). The data were analysed in order to establish (a) whether the PO2 values measured at the lung surface reflect intra-alveolar PO2 and (b) that the distribution of these values represent real physiological differences between alveoli. The mean PO2 values were related to the calculated mean alveolar PO2 (PAO2) values (r = 0.97) indicating that it is possible to study PAO2 by local measurements. It can therefore be concluded that the technique used allows the study of the influence of different FIO2 values on the distribution of PAO2. Each local PAO2 value is the result of the corresponding local ventilation/perfusion ratio (VA/Q) therefore the distribution of PAO2 values represents the distribution of VA/Q. An increasing FIO2 causes an increasing heterogeneity of PAO2 and thus VA/Q leading to a concomitant increase in the alveolo-arterial oxygen difference. At the moment it is not possible to decide if this heterogeneity is primarily caused by heterogeneities in perfusion or ventilation. The results could throw fresh light on the effect of different ventilation procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信