Elvis Boghiu, A. Maricel, M. Andrusca, A. Dragomir, A. Munteanu
{"title":"真空断路器控制开关的几个方面","authors":"Elvis Boghiu, A. Maricel, M. Andrusca, A. Dragomir, A. Munteanu","doi":"10.1109/SIELMEN.2017.8123302","DOIUrl":null,"url":null,"abstract":"The paper describes how different parameters from vacuum circuit breaker influence the closing and opening time. Operational voltage, ambient temperature or hydraulic pressure can introduce delays in opening and closing the circuit breaker. These parameters are motorized through sensors that send all the data to a control unit. The control unit calculates the decision/(time) when to make controlled switching. This paper presents a study case that demonstrates how one of the parameter introduces delays in the opening or closing processes of the circuit breaker.","PeriodicalId":403279,"journal":{"name":"2017 International Conference on Electromechanical and Power Systems (SIELMEN)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Aspects regarding controlled switching of the vacuum circuit breaker\",\"authors\":\"Elvis Boghiu, A. Maricel, M. Andrusca, A. Dragomir, A. Munteanu\",\"doi\":\"10.1109/SIELMEN.2017.8123302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes how different parameters from vacuum circuit breaker influence the closing and opening time. Operational voltage, ambient temperature or hydraulic pressure can introduce delays in opening and closing the circuit breaker. These parameters are motorized through sensors that send all the data to a control unit. The control unit calculates the decision/(time) when to make controlled switching. This paper presents a study case that demonstrates how one of the parameter introduces delays in the opening or closing processes of the circuit breaker.\",\"PeriodicalId\":403279,\"journal\":{\"name\":\"2017 International Conference on Electromechanical and Power Systems (SIELMEN)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Electromechanical and Power Systems (SIELMEN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIELMEN.2017.8123302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Electromechanical and Power Systems (SIELMEN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIELMEN.2017.8123302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Aspects regarding controlled switching of the vacuum circuit breaker
The paper describes how different parameters from vacuum circuit breaker influence the closing and opening time. Operational voltage, ambient temperature or hydraulic pressure can introduce delays in opening and closing the circuit breaker. These parameters are motorized through sensors that send all the data to a control unit. The control unit calculates the decision/(time) when to make controlled switching. This paper presents a study case that demonstrates how one of the parameter introduces delays in the opening or closing processes of the circuit breaker.