{"title":"电力系统静态电压稳定限值及弱母线识别","authors":"Z. Yao, S. Wen-nan","doi":"10.1109/TENCON.1993.320608","DOIUrl":null,"url":null,"abstract":"This paper develops a new approach to find the power system static voltage stability limit using the conventional load flow solution method. The developed approach proposes a load admittance model to replace the load injection only on the heaviest load bus. Tested results in several systems show that the approach has advantages in terms of simplicity, flexibility, rapidity and accuracy. Based on the investigation of the voltage stability limits for the load buses, it is easy to identify the weak bus of the power system.<<ETX>>","PeriodicalId":110496,"journal":{"name":"Proceedings of TENCON '93. IEEE Region 10 International Conference on Computers, Communications and Automation","volume":"456 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Power system static voltage stability limit and the identification of weak bus\",\"authors\":\"Z. Yao, S. Wen-nan\",\"doi\":\"10.1109/TENCON.1993.320608\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper develops a new approach to find the power system static voltage stability limit using the conventional load flow solution method. The developed approach proposes a load admittance model to replace the load injection only on the heaviest load bus. Tested results in several systems show that the approach has advantages in terms of simplicity, flexibility, rapidity and accuracy. Based on the investigation of the voltage stability limits for the load buses, it is easy to identify the weak bus of the power system.<<ETX>>\",\"PeriodicalId\":110496,\"journal\":{\"name\":\"Proceedings of TENCON '93. IEEE Region 10 International Conference on Computers, Communications and Automation\",\"volume\":\"456 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of TENCON '93. IEEE Region 10 International Conference on Computers, Communications and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TENCON.1993.320608\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of TENCON '93. IEEE Region 10 International Conference on Computers, Communications and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.1993.320608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power system static voltage stability limit and the identification of weak bus
This paper develops a new approach to find the power system static voltage stability limit using the conventional load flow solution method. The developed approach proposes a load admittance model to replace the load injection only on the heaviest load bus. Tested results in several systems show that the approach has advantages in terms of simplicity, flexibility, rapidity and accuracy. Based on the investigation of the voltage stability limits for the load buses, it is easy to identify the weak bus of the power system.<>