采用控制器改进并联有源滤波器直流母线电压时域参数

R. Sriranjani, S. Jayalalitha
{"title":"采用控制器改进并联有源滤波器直流母线电压时域参数","authors":"R. Sriranjani, S. Jayalalitha","doi":"10.1109/ICONRAEECE.2011.6129778","DOIUrl":null,"url":null,"abstract":"In power system, the nonlinear load affects the power quality such as harmonics of the supply system. In this paper, the diode rectifier is used as load which distorts the supply current. This supply current harmonics are reduced by the Shunt active filter (SAF) which injects the harmonic current to the load. So supply is free from harmonics. The synchronous reference frame theory is used to extract the fundamental component of the supply current which is the reference current for the hysteresis controller. The hysteresis controller tunes the SAF so that it generates the current equal in magnitude and opposite in phase with the nonlinear load. So the total harmonic distortion (THD) of supply current is greatly reduced. In this paper the SAF dc bus voltage is maintained constant using PI / PID controller and time domain specification of the bus voltage is analyzed using Matlab simulink and the results are presented.","PeriodicalId":305797,"journal":{"name":"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING","volume":"154 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Improvement of the time domain specifications of dc bus voltage of shunt active filter using controllers\",\"authors\":\"R. Sriranjani, S. Jayalalitha\",\"doi\":\"10.1109/ICONRAEECE.2011.6129778\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In power system, the nonlinear load affects the power quality such as harmonics of the supply system. In this paper, the diode rectifier is used as load which distorts the supply current. This supply current harmonics are reduced by the Shunt active filter (SAF) which injects the harmonic current to the load. So supply is free from harmonics. The synchronous reference frame theory is used to extract the fundamental component of the supply current which is the reference current for the hysteresis controller. The hysteresis controller tunes the SAF so that it generates the current equal in magnitude and opposite in phase with the nonlinear load. So the total harmonic distortion (THD) of supply current is greatly reduced. In this paper the SAF dc bus voltage is maintained constant using PI / PID controller and time domain specification of the bus voltage is analyzed using Matlab simulink and the results are presented.\",\"PeriodicalId\":305797,\"journal\":{\"name\":\"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING\",\"volume\":\"154 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICONRAEECE.2011.6129778\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICONRAEECE.2011.6129778","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在电力系统中,非线性负荷会影响供电系统的谐波等电能质量。本文采用二极管整流器作为负载,使电源电流产生畸变。通过将谐波电流注入负载的并联有源滤波器(SAF)减少了供电电流的谐波。所以电源没有谐波。采用同步参考系理论提取电源电流的基元分量,作为迟滞控制器的参考电流。滞回控制器对SAF进行调谐,使其产生与非线性负载大小相等、相位相反的电流。从而大大降低了电源电流的总谐波失真(THD)。本文采用PI / PID控制器实现了SAF直流母线电压的恒定控制,并利用Matlab simulink对母线电压的时域特性进行了分析,给出了结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improvement of the time domain specifications of dc bus voltage of shunt active filter using controllers
In power system, the nonlinear load affects the power quality such as harmonics of the supply system. In this paper, the diode rectifier is used as load which distorts the supply current. This supply current harmonics are reduced by the Shunt active filter (SAF) which injects the harmonic current to the load. So supply is free from harmonics. The synchronous reference frame theory is used to extract the fundamental component of the supply current which is the reference current for the hysteresis controller. The hysteresis controller tunes the SAF so that it generates the current equal in magnitude and opposite in phase with the nonlinear load. So the total harmonic distortion (THD) of supply current is greatly reduced. In this paper the SAF dc bus voltage is maintained constant using PI / PID controller and time domain specification of the bus voltage is analyzed using Matlab simulink and the results are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信